Product Information
Version: V2.0 2021/04/07
Manufacturer: Showven Technologies Co., Ltd.
Safety Considerations:
- Please read this manual carefully before operating this product.
- Warranty card attached in the manual, please keep it well.
Description:
This product is a smoke machine with various settings and features.
Technical Specifications:
Operation Panel | Interface | Error Information | Setting Menu | Advanced Menu |
---|---|---|---|---|
1. Control button area | 1. Main interface | Error information | Press MENU to | |
switch through setup menu | Press MENU for 3s to enter advanced setting |
interface
MENU: switch through setup menu
+/-: Parameter up/down
ENTER: confirm and save parameters
STOP: multiplex| First Line: DMX address, : blinks when there is DMX in
signal.
Second Line: shows machine core temperature and pressure.
The machine is ready for operation only when both temperature and
pressure values are close to 100%.| | Error Code| Explanation
---|---
E0| System IC Circuit fault
E1| Pressure faults, no fog fluid or pump error
E2| Temperature sensor fault
E3| Evacuate fuel pipe fault
E5| Circuit fault
E6| Heating element damage or circuit fault
| Options| Range
---|---
DMX 512 Address| 1-506
Power Regulation| Standard/Half Power
Color Optional| 0-10
Single Channel| ON/OFF
| Item| Value| Explanation
---|---|---
Manual Evacuate| ON/OFF| Manual Evacuate when pressure always insufficient
Interval Set| 0-200| Interval time
Duration Set| 0-8| Smoke output duration
Wireless Remote| ON/OFF| Wireless ON/OFF switch
Language| Chinese/English| Language switch
Manual Pump| ON/OFF| For maintenance
DMX Channel| 11| DMX channels for SONICBOOM.
DMX Channels and Functions:| Channel| Function
---|---
Channel 1| Firing: (0-9) OFF, (10-255) ON
Channel 2| Inner LED RED: (0-9) OFF, (10-255) LED brightness increase
Channel 3| Inner LED GREEN: (0-9) OFF, (10-255) LED brightness
increase
Channel 4| Inner LED BLUE: (0-9) OFF, (10-255) LED brightness
increase
Channel 5| Outer LED RED: (0-9) OFF, (10-255) LED brightness increase
Channel 6| Outer LED GREEN: (0-9) OFF, (10-255) LED brightness
increase
Channel 7| Outer LED BLUE: (0-9) OFF, (10-255) LED brightness
increase
Channel 8| LED Random: (0-9) OFF, (10-255) LED random color, use together
with channel 9.
Product Usage Instructions
Main Interface:
The main interface displays the DMX address, machine core temperature, and
pressure. The machine is ready for operation when both temperature and
pressure values are close to 100%.
Error Information:
The error information section provides codes and explanations for various
error conditions that may occur during operation.
Setting Menu:
Press the MENU button to navigate through the setup menu. The menu options
include:
- DMX 512 Address: Set the DMX address (range: 1-506).
- Power Regulation: Set the working power for the machine (options: Standard/Half Power).
- Color Optional: Set the LED color when manually firing (range: 0-10).
- Single Channel: Set the mode to single channel ON/OFF.
Advanced Menu:
Press the MENU button for 3 seconds to enter the advanced setting interface.
The advanced menu options include:
- Manual Evacuate: Enable/Disable manual evacuation when pressure is always insufficient.
- Interval Set: Set the interval time (range: 0-200).
- Duration Set: Set the smoke output duration (range: 0-8).
- Wireless Remote: Turn ON/OFF the wireless remote.
- Language: Switch between Chinese and English language.
- Manual Pump: Turn ON/OFF the manual pump for maintenance purposes.
- DMX Channel: SONICBOOM supports 11 DMX channels.
DMX Channels and Functions:
The DMX channels control various functions of the product. The functions
assigned to each channel are as follows:
Channel | Function |
---|---|
Channel 1 | Firing: (0-9) OFF, (10-255) ON |
Channel 2 | Inner LED RED: (0-9) OFF, (10-255) LED brightness increase |
Channel 3 | Inner LED GREEN: (0-9) OFF, (10-255) LED brightness |
increase
Channel 4| Inner LED BLUE: (0-9) OFF, (10-255) LED brightness
increase
Channel 5| Outer LED RED: (0-9) OFF, (10-255) LED
USER MANUAL SONICBOOM® X SMOKEJET
- Please read this manual carefully before operating this product.
- Warranty card attached in the manual, please keep it well.
SAFETY CONSIDERATIONS
- Unauthorized repair are prohibited, it may cause serious incident
- Independent smoke column color change
- Patented pipeline integration technology, ensure 0.3s instant smoke burst
- Automatic constant pressure design, highly consistent smoke effect
- 220V version SONICBOOM Support 1500W half power mode, easier main power supply.
- Over temp. alarm, no fuel alarm, over voltage alarm etc. multi safety status monitoring. Safer for use, easier for maintenance.
- Support manual operation on machine control panel
- DMX control, 11 channels and 1 channel optional
- Only use SHOWVEN original FX-S/FX-ST fog fluid, other fluid may lead to clog or malfunction. \ FX-S is quick dissipating fog fluid, the smoke dissipate in seconds, it is perfect choice for creating instant smoke column.
Description
SONICBOOM X SOMEKJET can generate up to 10m smoke column effects similar as
CO2 jet. 35 pcs of LED ensure the multi color of smoke. Combined with SHOWVEN®
original FX-S pro quick dissipating fog fluid guarantee the fast dissipating
of the smoke.
Technical Specifications
- MODEL: SONICBOOM® X
- DIMENSION: 482×408×215mm
- WEIGHT: 17.2kg
- VOLTAGE: 220V/110V, 50/60Hz
- FUSE:15A/250V
- POWER: 3000W/1500W(220V), 2000W(110V) \ LED POWER: 5W×35pcs
- MAX OUTPUT DISTANCE: 10m
- MAX CONTINUOUS OUTPUT DURATION: 8s \ SMOKE OUTPUT: 55000cuft/min
- TANK CAPACITY: 2.5L
- FLUID CONSUMPTION RATE: 5min/L
- DMX CHANNELS: 1/11
- CONSUMABLES: FX-S
Operation Panel
Control button area
- MENU: switch through setup menu
- +: Parameter up; multiplex “TIMER” (smoke output time)
- -: Parameters down; multiplex “VOLUME” (smoke output start)
- ENTER: confirm and save parameters (screen will blink once when save successfully); multiplex “STOP”.
- NOTE: Screen will switch to main interface automatically if not press any button in long time.
Interface
Main interface:
First Line: DMX address, “:” blinks when there is DMX in signal.
Second Line: shows machine core temperature and pressure. The machine ready
for operate only when both temperature and pressure value close to 100%.
Error information:
Example of “TIMER” setting function in the menu:
-
“set interval 10s”
-
“set duration 2s”
SONICBOOM will repeat: firing 2s, interval of 10s, firing 2s, interval 10s…
Press “VOLUME” button under main interface, SONICBOOM activated and start to generate smoke, and press “STOP” to stop the machine. -
Setting Menu:
Options| Range| Explanation
---|---|---
DMX 512 Address| 1~506| Set DMX address
Power Regulation| Standard/Half Power| Setting working power for the machine
Color Optional| 0~10| LED color set when manual firing
Single Channel| ON/OFF| Single channel mode set
Press “MENU” switch through setup menu.
- LED color setting:
0: LED OFF 1: RED 2: GREEN 3: BLUE 4: PINK
5: PURPLE 6: ORANGE 7: YELLOW 8: SKY BLUE 9: WHITE
Above setting disabled when use DMX console, LED color determined by setting on console. When choose 1 channel mode, LED color determined by single channel, DMX value and related color as below:Color| SMOKE OFF| RED| GREE N| BLUE| PINK| PURPL E| ORAN GE| YELLO W| SKY BLUE| WHIT E| Rando m| LED OFF
---|---|---|---|---|---|---|---|---|---|---|---|---
DMX
value
| 0-40| 41-
60
| 61-80| 81-
100
| 101-
120
| 121-
140
| 141-
160
| 161-
180
| 181-200| 201-
220
| 221-
235
| 236-255
5. Advanced Menu:
Press “MENU” for 3s, enter advanced setting interface Item| Value|
Explanation
---|---|---
Manual Evacuate| ON/OFF| Manual Evacuate when pressure always insufficient
Interval Set| 0-200| Interval time
Duration Set| 0-8| Smoke output duration
Wireless Remote| ON/OFF| Wireless ON/OFF switch
Language| Chinese/English| Language switch
Manual Pump| ON/OFF| For maintenance
DMX Channel
11 DMX channels for SONICBOOM.
Channels | Function |
---|---|
Channel 1 | Firing: (0-9) OFF, ( 10-255) ON |
Channel 2 | Inner LED RED: (0-9) OFF, (10-255) LED brightness increase |
Channel 3 | Inner LED GREEN: (0-9) OFF, (10-255) LED brightness increase |
Channel 4 | Inner LED BLUE: (0-9) OFF, ( 10-255) LED brightness increase |
Channel 5 | Outer LED RED: (0-9) OFF, (10-255) LED brightness increase |
Channel 6 | Outer LED GREEN, (0-9) OFF, (10-2551) LED brightness increase |
Channel 7 | Outer LED BLUE, (0-9) OFF, (10-255) LED brightness increase |
Channel 8 | LED Random: (0-9) OFF, (10-255) LED random color, use together with |
channel 9.
Channel 9| LED color change speed: (0-9) OFF, (10-255) LED color change speed
increase
---|---
Channel 10| LED strobe: (0-9) OFF, (10-255) LED strobe increase
Channel 11| LED dimmer, (0-9) OFF, (10-255) LED brightness increase
NOTE: Manual function disabled when DMX connected.
E1 Pressure error explanation
In order to protect pump, SONICBOOM will running self check program to find
out whether there are fog fluid in the fuel pipe.
-
E1 pressure error activation
When there is no fog fluid in the fuel tank, system can not reach preset pressure even turn on for a long time. The pump will stop working, and report E1. -
Way to clear E1 error
-
Fill the fog fluid tank, then restart the machine.
-
Press “VOLUME” to reset.
-
DMX Channel 1, start a firing.
Upside-down installation
For upside-down installation, please remove the bottom panel of fluid tank,
and installed to the other side (top panel), the fluid tank should installed
upward as below picture. For safety, hanging installation should install
safety rope.
Maintenance
- Use SHOWVEN original fog fluid for the best effect of SONICBOOM. Warranty will be void if any other type fluid is used.
- Don’t disassemble the machine by unauthorized person, modifications to the machine are not allowed.
- Excessive dust, liquid or dirt etc on the equipment will affect performance of the machine and cause poor heat dissipation. Remove dust with air compressor, vacuum or soft brush. Use a damp cloth to clean the case.
- Before storing the machine, run distilled water through the system to help avoid condensing the pump or heater.
- To keep the best status and performance of machine, it is recommended to running the machine at least once per month.
- After continuous use of 40h (or 1-2month), please use 35% vinegar with 65% distilled water to wash the pump and pipe system by running the machine 10-15 times.
Possible reason for the block of atomizer
For healthy and best status of machine, please do use SHOWVEN original fog
fluid.
-
A. Fluid spill: heat can’t effectively transmit to fog fluid, leads to insufficient atomization of the fog fluid in the heating pipe.
Possible Reason 1: Use other type of low quality fog fluid instead of SHOWVEN original fog fluid.
Possible reason 2: Use inappropriate fog fluid. For different types of fog fluid, the atomization temperature is different. -
B. Heating aluminum pipe clog: early symptom for heating aluminum pipe clog is fog fluid spill caused by insufficient atomization. Use other brand fluid or not make regular maintenance for a long time will definitely leads to pipe clog.
-
C. Solution for above problem: Use SHOWVEN original fog fluid. Make regular maintenance (every 1-2month). Use 35% vinegar with 65% distilled water to wash the pump and pipe system by running the machine 10-15 times.
Warranty Instructions
- Sincere thanks for your choosing our products, you will receive quality service.
- The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you
- We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors)in warranty period. Please don’t repair machine without factory permission
Below situations NOT included in warranty service:
- Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
- Disassemble, modify or repair products without permission;
- Damage caused by external reasons (lightning strike, power supply etc.)
- Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid service. Invoice and warranty card are necessary when applying for maintenance service from SHOWVEN.
Warranty Card
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn
E-mail: info@showven.cn
Add: Liuyang Economic Development Zone, Changsha, 410300, Hunan Province,
P.R.China