BEGA 50535.1 Ceiling and Wall Luminaire for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
IP 64
50 535.1
Technical amendments reserved
Ceiling and wall luminaire for indoor use
Instructions for use
50535.1 Ceiling and Wall Luminaire for Indoor Use
Application
Ceiling and wall luminaire· indoor luminaire with high protection class for a
variety of lighting tasks.
A luminaire made of die cast aluminium and crystal glass.
Product description
Aluminium alloy housing, finish Colour white
Crystal glass, inside white
Silicone gasket
2 mounting holes ø 4.5 mm
Distance apart 110 mm
2 cable entries for through-wiring of mains
supply cable ø 7-10.5 mm
Connection terminal 2.5@
Earth conductor connection
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Safety mark
– Conformity mark
Weight: 0.95 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 4.1 W |
---|---|
Luminaire connected wattage | 5.8 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 30 °C |
50 535.1 K3
Module designation | LED-0337/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 670 lm |
Luminaire luminous flux | 365 lm |
Luminaire luminous efficiency | 62,9 lm / W |
Installation
Remove luminaire housing with glass from luminaire base by turning it counter-
clockwise.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Disassemble LED module.
Lead the mains supply cable through the cable entry into the luminaire back
housing.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.
Assemble LED module.
Make sure that gasket is positioned correctly.
Place luminaire housing with glass onto the luminaire base and turn it
clockwise as far as it will go.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass | 11 002 863 11R G |
---|---|
LED power supply unit | DEV-0212/500 |
LED module 3000 K | LED-0337/930 |
Gasket | 83 001 312 |
Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com