BEGA 50271 Recessed Ceiling Luminaire Tunable White for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
**BEGA 50271 Recessed Ceiling Luminaire Tunable White for Indoor Use Instruction Manual
**
Application
Recessed ceiling luminaire · indoor luminaire with hand-blown opal glass,
satin matt and metal housing and external LED power supply unit.
Luminaire with adjustable colour temperature (Tunable White).
They are ideal for places where a soft and uniform lighting distribution is
required.
For installation into ceilings with a shallow depth in interior areas.
Product description
Recessed LED ceiling luminaire · Downlight with a remote DALI controllable
power supply unit
Luminaire housing made of metal
Opal glass, satin matt, with screw neck Silicone gasket Ceiling aperture ø 208
mm
Free space installation depth required 45 mm
Fixing is achieved by using three adjustable wedge-shaped claws
2-pole connecting terminal for digital control
BEGA Ultimate Driver®
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
During DC operation the LED power is reduced to 50%
DALI controllable (Device Type 8 for Tunable
White according to IEC 62386-209)
Number of DALI addresses: 1
A basic isolation exists between power cable and control line
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class II
– Safety mark
– Conformity mark
Weight: 1.8 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage 21.4 W
Luminaire connected wattage 24.3 W
Rated temperature ta=25 °C
Ambient temperature ta max=30 °C
Module designation LED-0700/9TW
Colour temperature adjust. 2700-6500 K
Colour rendering index Ra > 90
Module luminous flux 2440 lm
Luminaire luminous flux 1488 lm
Luminaire luminous efficiency 61,2 lm/W
Setting the colour temperature
The LED colour temperature of the luminaire can be set from 2700 to 6500 K
(“Tunable White”).
Please note: To be able to set the LED colour temperature, the controller used
must support DALI Device Type 8. If no LED colour temperature setting is made,
3000 K will be used by default.
Installation
Luminaire housing must not be installed in heat-insulating material.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using three adjustable
wedgeshaped claws.
Installation into concrete ceilings:
For this purpose installation housing 13 018 is available.
Installation into inserted ceilings:
A recessed opening of ø 208 mm is necessary to accept the luminaire housing.
Recessed depth min. 45 mm.
The lateral distance between recessed luminaire and other building parts must
be at least 50 mm.
The claws catch the ceiling facing from the back side. Minimum thickness of
the ceiling facing is 3 mm. If the ceiling facing has a thickness of less than
10 mm or in case of an installation into plasterboard ceilings, the facing
thickness in the region of the claws must be increased from the back side.
Open luminaire:
Remove glass from luminaire housing by turning it counter-clockwise.
Open cover of the LED-power supply unit and lead mains supply cable into it.
Make electrical connection to the terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Close cover of the LED-power supply unit.
Push external LED power supply unit and luminaire housing into the ceiling
cut-out.
Luminaire housing and external LED power supply unit must not be installed in
heat-insulating material.
Tighten evenly screws of claw fasteners.
Screw the glass into the luminaire housing by turning it clockwise.
Make sure the seal is properly located.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free
cleansers from dirt.
Defective glass must be replaced.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
13 018 Installation housing
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass with gasket 11 003 088 40MRG
LED power supply unit DEV-0264/700
LED module LED-0700/9TW
Gasket glass 83 001 447
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>