BEGA 50216.1 LED Ceiling and Wall Luminaire
Dimension
Application
Ceiling and wall luminaire · indoor luminaire made of impact resistant
synthetic diffuser and aluminium housing.
Luminaire with free-radiating and uniform light distribution for linear
illumination in interior.
Product description
Luminaire made of Aluminium, finish Colour white
Light-diffusing synthetic luminaire cover 2 elongated fixing holes
Width 5.5mm · 900mm spacing
Connection terminal 2.5°
Earth conductor connection 2-pole connecting terminal for digital control LED
power supply unit
220-240 V 0/50-60 Hz
DC 176-276 V
During DC operation the LED power is reduced to 15%
DALI-controllable
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Impact strength IK04
Protection against mechanical impacts < 0.5 joule
– Safety mark
– Conformity mark
Weight: 2.7 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire!
Note:
If you a planning a linear arrangement of several luminaires, you must keep a minimum distance of 30mm between the luminaire caps for installation reasons.
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Remove the luminaire from the packaging and put it down so that the open rear
side of its housing rests on a soft surface.
Undo the lateral Torx countersunk screw T25 and remove the luminaire cap.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to the
terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Drill mounting holes into the mounting surface – spacing 900 mm Fix the
luminaire housing with enclosed or any other suitable fixing material onto the
mounting surface.
For wall installation note the position of application “arrow down”.
To prevent dirt accumulating on the LED modules, press the supplied plugs into
the housing holes of the luminaire profile above the screw-fitting points.
Clip the luminaire cover into the groove of the aluminium profile and push it
until the stop of the luminaire housing.
Replace the housing cap and tighten lateral Torx countersunk screw T25.
Lamp
Module connected wattage 34.8 W
Luminaire connected wattage 42 W
Rated temperature ta=25 °C
Ambient temperature ta max=50 °C
50 216.1K3
Module designation 4x LED-0694/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 5540 lm
Luminaire luminous flux 4760 lm
Luminaire luminous efficiency 113,3 lm/W
50 216.1K4
Module designation 4x LED-0694/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 5860 lm
Luminaire luminous flux 5035 lm
Luminaire luminous efficiency 119,9 lm/W
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Defective luminaire cover must be replaced. Close the luminaire.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Spares
Synthetic cover 15 000 481 .3
LED power supply unit DEV-0159/1050
LED module 3000 K L E D-0694/930
LED module 4000 K LED-0694/940
Customer Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden ·
info@bega.com ·
www.bega.com