24 049
IP 65
Wandleuchte
Instructions for use
Application
Wall luminaire with shielded light.
Light emission 90° / 15°.
The light is deflected by means of a conical reflector onto the surface to be
illuminated.
The luminaire can be installed in any burning position.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Borosilicate glass Silicone gasket Reflector made of pure
anodised aluminium Light sector 90° / 15° 2 mounting holes ø 4.8 mm Distance
apart 134 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5
mm Connecting terminal and earth conductor terminal 2.5@ LED power supply unit
220-240 V x 0/50-60 Hz DC 170-280 V BEGA Thermal Switch® Temporary thermal
shutdown to protect temperature-sensitive components Safety class I Protection
class IP 65 Dust-tight and protection against water jets Impact strength IK09
Protection against mechanical impacts < 10 joule
– Safety mark
****– Conformity mark Weight: 2.0 kg This product contains light sources of
energy efficiency class(es) C, D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
Lamp
Module connected wattage | 9.5 W |
---|---|
Luminaire connected wattage | 12.3 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
24 049 K3
Module designation| LED-0793/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 1545 lm
Luminaire luminous flux| 216 lm
Luminaire luminous efficiency| 17,6 lm / W
24 049 K4
Module designation| LED-0793/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 1695 lm
Luminaire luminous flux| 238 lm
Luminaire luminous efficiency| 19,3 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Undo hexagon socket head screws – wrench size 3 – up to the stop and lift
luminaire top. Pull plug-connection of the LED connecting cable carefull out
of the luminaire top.
Disconnect plug connection.
Lead the mains supply cable through the cable entry of the luminaire base.
Notice position of use “arrow down” of the luminaire back plate. Fix luminaire
base with enclosed or any other suitable fixing material onto the mounting
surface. Be sure to use the gasket rings supplied. Make the earth conductor
connection and the electrical connection.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire. Make earth conductor connection between luminaire top
and luminaire base. Push plug into coupler as far as it will go. Make sure
that gasket is positioned correctly. Install the luminaire top, press-on and
tighten screw.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module. Inspect and, if necessary, replace the
luminaire gaskets. Defective glass must be replaced. Close the luminaire.
Spares
Spare glass | 11 003 184 |
---|---|
LED power supply unit | DEV-0277/700 |
LED module 3000 K | LED-0793/830 |
LED module 4000 K | LED-0793/840 |
Reflector | 76 001 483 |
Gasket housing | 83 001 523 |
Gasket glass | 83 001 555 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com
Documents / Resources
| BEGA
24049 Wall
Luminaire
[pdf] Instruction Manual
24049K3, 24049K4, 24049 Wall Luminaire, Wall Luminaire, Luminaire
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>