BEGA 51016.2 Ceiling Luminaire for Indoor Use Instruction Manual

June 13, 2024
BEGA

51016.2 Ceiling Luminaire for Indoor Use
Instruction Manual 51 016.2
11.19
Technical amendments reserved

51016.2 Ceiling Luminaire for Indoor Use

Ceiling luminaire for indoor use

Instructions for use

Application

Ceiling luminaire · indoor luminaire impact resistant synthetic diffuser and metal housing for non-glare light deflected downwards.

Product description

Ceiling luminaire »STUDIO LINE«
Aluminium luminaire housing, finish Colour velvet black inside hue aluminium matt
Metal luminaire mounting plate, finish Colour velvet black
Impact resistant synthetic diffuser, white, with bayonet closure 2 mounting holes ø 5.5 mm
Distance apart 230 mm 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
Connection terminal 2.5@
Earth conductor connection
Lampholder E 27
Safety class I
– Safety mark
– Conformity mark
Weight: 2.6 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Luminaire with lampholder E 27
Lamp output max. 2 × 25 W
This product contains light sources of energy efficiency class E
51 016.2 K3
inclusive BEGA LED lamp 13592 dimmable

LED 12 W 1400 lm
Colour temperature 3000 K

Detailed technical and lighting data for the lamps can be found in the data sheets on our website.

Installation

Before installing onto the ceiling the luminaire mounting plate must be inserted into the luminaire housing.
Thereby pass the mains supply cable through the grommet into luminaire mounting plate.
Fix monting plate inside the luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
Dismantle the mains supply cable approx. 60 mm.
Pull silicone sleeves over the wires and make earth and electrical connection to the terminals.
Insert lamps.
In order to securely install the synthetic cover in the fitting, the top opening of the synthetic cover must be inserted into the luminaire housing at an angle.
Make sure that at least one of the recesses in the edge of the synthetic cover matches the position of one of the lugs on the fitting – see drawing.
IMPORTANT:
Turn the synthetic cover upwards into the fitting as far as it will go. Now secure the synthetic cover in the fitting by turning it clockwise.
Only then is the synthetic cover held securely in place and resistant to vibration.
The synthetic cover is removed by turning it anti-clockwise as far as it will go while simultaneously pushing the synthetic cover up against the luminaire fitting.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Relamping
Disconnect from main supply.
Unscrew synthetic diffuser from luminaire housing by turning it counter- clockwise.
Change the lamps.
Screw in synthetic diffuser by turning it clockwise.
A damaged synthetic diffuser must be replaced.

Spares

LED lamp 13 592
Synthetic cover 15 000 633
Lampholder 63 000 585
Shield 71 001 760 L12

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals