Floor lamp for indoor use
Instructions for use
Application
Floor lamp · indoor luminaire with impact resistant synthetic diffuser and metal housing for shielded light, deflected upwards and downwards.
Product description
Floor lamp »STUDIO LINE«
Metal housing, finish Colour velvet black
Aluminium housing shield,
Finish Colour velvet black inside hue matt brass
Impact-resistant synthetic cover, translucent white
Touch-controlled dimmer for infinite light adjustment
Black cable · 2 m, with safety plug
LED power supply unit 220-240 V 50-60 Hz
BEGA Thermal Control ®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
– Conformity mark
Weight: 16.7 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 40.6 W |
---|---|
Luminaire connected wattage | 45.5 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 55 °C |
50 753.4 K3
Module designation | LED-0832/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 6640 lm |
Luminaire luminous flux | 4152 lm |
Luminaire luminous efficiency | 91,3 lm / W |
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Carefully remove the floor lamp from its packaging and set it up. Make sure
that the luminaire is in a firm and secure position.
Connect luminaire to mains supply (230 V). Press sensing device gently to turn
the luminaire on or off.
Holding the sensing device enables to adjust the light intensity infinitely.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
We recommend that you dry-clean the sensing device.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective luminaire cover must be replaced.
Close the luminaire.
Spares
Synthetic cover | 15 000 633 |
---|---|
LED power supply unit | DEV-0338/1050i |
LED module 3000 K | LED-0832/930 |