 50137.2 Wall Luminaire for Indoor Use

Wall luminaire for indoor use

Instructions for use

Application

Free-radiating wall wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing.
The character of the three-ply opal glass creates a smooth and uniform light distribution in the room.

Product description

Glass holder made of matt brushed aluminium
Hand-blown opal glass, satin matt 2 mounting holes ø 6 mm
Distance apart 30 mm
Connection terminal 2.5@
Earth conductor connection
Installation surface 145 x 35 mm
LED-Module for mains voltage 220-230 V 50/60 Hz
BEGA Thermal Switch ®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
– Safety mark
**** – Conformity mark
Weight: 0.65 kg
This product contains light sources of energy efficiency class(es) F

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp

Luminaire connected wattage 10 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 30 °C

50 137.2 K3

Module designation LED-0607/930
Colour temperature 3000 K
Colour rendering index Ra > 90
Module luminous flux 940 lm
Luminaire luminous flux 779 lm
Luminaire luminous efficiency 77,9 lm / W

Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire!

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Make earth conductor connection to the earthing screw ( ****) on the reverse side of the glass holder.
Push silicone sleeves over the lines and make electrical connection.
The mounting of the glass holder requires two holes drilled into the wall.
The locking pin of the glass holder is to be inserted into the lower hole, the upper hole is used for fastening.
Fix glass holder with enclosed or any other suitable fixing material onto the mounting surface.
Note position of application “arrow down”.
Place glass with its opening over the LED module. The magnet fixes the glass on the glass holder. Align glass vertically

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by a qualified electrician or a comparably qualified person using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.
Spares

Spare glass 11 003 249 .0B 1RG
LED module 3000 K LED-0607/930

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com