BEGA 50131 Wall Luminaire for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
50131 Wall Luminaire for Indoor Use
Instruction Manual 30.21
**** 50 131
Technical amendments reserved
50131 Wall Luminaire for Indoor Use
Wall luminaire for indoor use Instructions for use
Application
Open and free-radiating wall luminaire · indoor luminaire with hand-blown opal
glass and metal bracket.
The character of the opal glass creates a smooth and uniform light
distribution in the room.
Product description
Aluminium fitter, finish Colour white
Stainless steel glass holding bolts
Hand-blown opal glass 3 fixing holes ø 6.5 mm
105 x 160 mm spacing 2 cable entries for through-wiring for mains cable up to
ø 10.5 mm max. 3 × 1.5@
Connection terminal 2.5@
Earth conductor connection
LED-Module for mains voltage 220-230 V 50/60 Hz
Safety class I
– Safety mark
****– Conformity mark
Weight: 0.75 kg
This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Luminaire connected wattage | 10 W |
---|---|
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 30 °C |
50 131 K3
Module designation | LED-0607/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | Ra > 90 |
Module luminous flux | 940 lm |
Luminaire luminous flux | 723 lm |
Luminaire luminous efficiency | 72,3 lm / W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Notice position of use “arrow down” of the luminaire base.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
Mount glass to luminaire base with the glass holding bolts.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by a
qualified electrician or a comparably qualified person using standard tools.
Disconnect the system.
Remove glass by unscrewing glass holding bolts.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Mount glass to luminaire base with the glass holding bolts.
Spares
Spare glass | 11 002 801 .1R G |
---|---|
Glass holding bolt | 51 003 272 |
LED module 3000 K | LED-0607/930 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>