Instructions for use
Application
Wall luminaire with directed light. The flush luminaire glass distributes the
light broad and uniformly onto the mounting surface. The luminaire can be
installed with the light distribution opening upwards or downwards.
Lamp
Module connected wattage 3 W
Luminaire connected wattage 4.1 W
Rated temperature ta=25 °C
Ambient temperature ta max=55 °C
33 223K3
Module designation LED-0291/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 550 lm
Luminaire luminous flux 365 lm
Luminaire luminous efficiency 89 lm/W
Product description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or silver
- Safety glass with optical structure
- Silicone gasket 2 mounting holes ø 5.5mm
- Distance apart 82mm 1 cable entry for mains supply cable up to ø 10,5mm
- Connecting terminal 2.5@ with plug connection
- Earth conductor connection
- BEGA Ultimate Driver®
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-264 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- Impact strength IK06
- Protection against mechanical impacts < 1 joule
- Safety mark
- Conformity mark
- Weight: 0.75 kg
- This product contains light sources of energy efficiency class(es) C
Dark Sky
The light from this luminaire is directed evenly and highly efficiently onto
the surface to be illuminated and emits less than 1% of the luminaire luminous
flux into the upper halfspace of the luminaire.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e.g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the screws and lift off the luminaire top. Lead the mains supply cable through the cable entry of the luminaire base. Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection to terminal (plug connection). Make sure that gasket is positioned correctly. Install the luminaire top, press-on and tighten screws evenly
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Inspect and,
if necessary, replace the luminaire gaskets. Defective glass must be replaced.
Close the luminaire.
Spares
LED power supply unit DEV-0303/350
LED module 3000 K LED-0291/830
Gasket 83 001 417
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden ·
info@bega.com
www.bega.com