Product Information

Product Name: Decken- und Wandleuchte Ceiling and wall luminaire Plafonnier et applique

Dimensions: 290 x 45

Power: 1100

IP Rating: IP 65

Application: Ceiling and wall luminaire with free-radiating and uniform light distribution. Suitable for linear illumination in interior and exterior applications.

Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. Additional overvoltage protection components are recommended for extra protection. These components can be found on our website at www.bega.com.

Safety: The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning. The manufacturer is not liable for any damage caused by improper use or installation. Any modifications made to the luminaire should be done by a qualified person.

Lamp Specifications:

  • Lamp Module connected wattage: 47.4 W
  • Luminaire connected wattage: 54.4 W
  • Rated temperature: 25 – 50°C
  • Ambient temperature: max = ta
  • Module designation: LED-0772/830
  • Colour temperature: 3000 K
  • Colour rendering index (CRI): > 80
  • Module luminous flux: 8850 lm
  • Luminaire luminous flux: 3419 lm
  • Luminaire luminous efficiency: 62.8 lm / W

Installation Instructions:

  1. Undo hexagon socket screws (wrench size 3) and lift the mounting bar out of the luminaire housing.
  2. Lead the mains supply cable through the opening of the mounting bar.
  3. Fix the mounting bar onto the mounting surface using enclosed or other suitable fixing material. Ensure an even mounting surface.
  4. Undo hexagon socket screws and remove the connectingcompartment cover from the luminaire housing.
  5. Lead the mains supply cable through the cable entry of the connecting compartment cover.
  6. In case of through-wiring, remove the factory-installed dummyplug.

Dimension

Ceiling and wall luminaireBEGA-24320-Ceiling-and-Wall-Luminaire-fig
1

Application

  • Ceiling and wall luminaire with free-radiating and uniform light distribution.
  • By arraying single luminaires in line light bands of different length can be arranged.
  • A luminaire for linear illumination in interior and exterior application.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • White safety glass · Silicone gasket
  • Mounting bar with 2 elongated holes
  • 7 mm width, 1100 mm spacing
  • 2 screw cable glands with strain relief for through-wiring of the mains supply cablefrom ø 7,5–10,8 mm, max. 5 G 1,5@
  • 1 screw cable gland closed at the factory with a dummy plug
  • Connecting terminal 2.5@
  • with plug connection
  • Earth conductor connection
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • During DC operation the LED power is reduced to 15 %
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Ballproof – The testing of ball impact safety was carried out exclusively with handballs in accordance with DIN 18032-3: 2018-11. Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK05
  • Protection against mechanical
  • impacts < 0.7 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 9.1 kg
  • This product contains light sources of energy efficiency class(es) C

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Module connected wattage 47.4 W

  • Luminaire connected wattage 54.4 W

  • Rated temperature ta = 25 °C

  • Ambient temperature ta max = 50 °C
    24 320 K3

  • Module designation LED-0772/830

  • Colour temperature 3000 K

  • Colour rendering index CRI > 80

  • Module luminous flux 8850 lm

  • Luminaire luminous flux 3419 lm

  • Luminaire luminous efficiency 62,8 lm / W
    24 320 K4

  • Module designation LED-0772/840

  • Colour temperature 4000 K

  • Colour rendering index CRI > 80

  • Module luminous flux 9090 lm

  • Luminaire luminous flux 3515 lm

  • Luminaire luminous efficiency 64,6 lm / W

Installation

  • Undo hexagon socket screws (wrench size 3) and lift mounting bar out of luminaire housing.
  • Lead mains supply cable through the opening of the mounting bar.
  • Fix mounting bar with enclosed or other suitable fixing material onto mounting surface.
  • It is absolutely essential to have an even mounting surface. Undo hexagon socket screws and remove connecting compartment cover from the luminaire housing.BEGA-24320-Ceiling-and-Wall-Luminaire-fig 4
  • Lead mains supply cable through the cable entry of the connecting compartment cover. In case of through-wring remove the factory installed dummy plug.
  • Tighten screw cable gland.
  • Make earth conductor connection and electrical connection to the connecting terminal (plug connection).
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
  • Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
  • Push plug into coupler as far as it will go.
  • Assemble connecting compartment cover.
  • Make sure that the gasket is positioned correctly.
  • Hang the luminaire housing in the mounting rail and screw it in place.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Housing + Glass graphite 25 000 115
  • LED power supply unit DEV-0214/1050
  • LED module 3000 K LED-0772/830
  • LED module 4000 K LED-0772/840
  • Gasket connection housing 83 001 866
  • Gasket housing 83 002 131

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com