BEGA 50222.1 Wall Luminaire for Indoor Use Instruction Manual

June 13, 2024
BEGA

BEGA 50222.1 Wall Luminaire for Indoor Use

Product Information

Safety| The installation and operation of this luminaire are subject to
national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
---|---
Overvoltage Protection| The electronic components installed in the luminaire are
protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients and other events, it is recommended to use separate overvoltage protection components, which can be found on our website at www.bega.com.
Replacement of the LED Module| The designation of the LED module is noted on a label in the
luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. The defective glass must be replaced. Close the luminaire.

Product Usage Instructions

Installation and Safety

  1. Ensure that the installation and operation of the luminaire comply with national safety regulations.
  2. Installation and commissioning should only be carried out by a qualified electrician.
  3. Improper use or installation may cause damage, for which the manufacturer cannot be held liable.
  4. If any modifications are made to the luminaire, the person responsible for these modifications is considered the manufacturer.

Overvoltage Protection

The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection against transients and other events, it is recommended to use separate overvoltage protection components. These components can be found on our website at www.bega.com.

Replacement of the LED Module

  1. Identify the designation of the LED module on the label in the luminaire.
  2. Ensure that the light color and light output of the replacement module match those of the original module.
  3. Qualified persons can replace the LED module using standard tools.
  4. Disconnect the system and open the luminaire according to the installation instructions.
  5. If the glass is defective, it should be replaced.
  6. Close the luminaire after completing the replacement.

Dimensions

Application

  • Free-radiating wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks in interior applications.
  • They are ideal for places where a soft and uniform lighting distribution is required.
  • Luminaire with a high protection class.

Product Description

  • Die-cast aluminium and aluminium housing, finish Colour white
  • Hand-blown opal glass, satin matt
  • 4 mounting holes ø 5 mm
  • Distance 240 x 65 mm
  • 1 cable entry for mains supply cable
  • up to ø 10.5 mm max. 3 x 1.5
  • Connection terminal 2.5
  • Earth conductor connection
  • Built-in toggle switch
  • LED power supply unit
  • 220-240 V 0/50-60 Hz
  • DC 170-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • : Safety mark
  • CE: Conformity mark
  • Weight: 0.85 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Specifications

Lamp

  • Module connected wattage: 5.8 W
  • Luminaire connected wattage:  7.8 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 50 °C

50 222.1 K27

  • Module designation: LED-0572/927
  • Color temperature: 2700 K
  • Color rendering index: CRI > 90
  • Module luminous flux: 935 lm
  • Luminaire luminous flux: 676 lm
  • Luminaire luminous efficiency: 86,7 lm / W

50 222.1 K3

  • Module designation: LED-0572/930
  • Color temperature:  3000 K
  • Color rendering index: CRI > 90
  • Module luminous flux: 965 lm
  • Luminaire luminous flux: 698 lm
  • Luminaire luminous efficiency: 89,5 lm / W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Lead the mains supply cable through the grommet into the luminaire housing.
  • Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
  • It is imperative to use the enclosed gaskets.
  • Make earth conductor connection electrical connection to the terminals.
  • Loosen screw of the lateral cover.
  • Position glass into the luminaire housing and fix it with the screw and the cover.

Maintenance

Cleaning /Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • The defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass: 11 003 116 .0R G
  • LED power supply unit: DEV-0189/350
  • Switch: 63 000 430 B
  • LED module 2700 K: LED-0572/927
  • LED module 3000 K: LED-0572/930

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals