BEGA 50125.4 Wall Luminaire for Indoor Use
Product Information
- Metal housing, finish Brass
- Hand-blown opal glass, satin matt
- Mounting plate with 2 fixing Earth conductor connection
- LED-Module for mains voltage 220-230 V y 50/60 Hz
- Temporary thermal shutdown to protect temperature-sensitive components
- Weight: 0.85 kg
- This product contains light sources of energy efficiency class(es) G
Product Usage Instructions
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Dimension
Instructions for use
Application
Free-radiating wall luminaire · indoor luminaire made of hand-blown opal
glass, satin matt and metal housing.The character of the three-ply opal glass
creates a smooth and uniform light distribution in the room.
Product description
Metal housing, finish Brass Hand-blown opal glass, satin matt Mounting plate
with 2 fixing holes ø 6 mm · 70 mm spacing 1 cable entry for mains supply
cable up to ø 10.5 mm max. 3 x 1.5@ Connection terminal 2.5@ Earth conductor
connection LED-Module for mains voltage 220-230 V y 50/60 HzBEGA Thermal
Switch® Temporary thermal shutdown to protect temperature-sensitive components
Safety class Ir – Safety mark c – Conformity mark Weight: 0.85 kgThis product
contains light sources of energy efficiency class(es) G
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve additional protection
againste. g. transients, etc. we recommend separate overvoltage protection
components. You can find them on our website at
www.bega.com.
- Lamp
- Luminaire connected wattage 7.4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 30 °C
- 50 125.4 K3
- Module designation LED-0662/930
- Colour temperature 3000 K
- Colour rendering index Ra > 90
- Module luminous flux 660 lm
- Luminaire luminous flux 437 lm
- Luminaire luminous efficiency 59,1 lm / W.
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping. Take off
the glass from luminaire base. Lead the mains supply cable through the cable
entry of the luminaire base. Fix luminaire base with enclosed or any other
suitable fixing material onto the mounting surface. Be sure to use the gasket
rings supplied. Notice the position of use “arrow down” of the luminaire base.
Establish earth conductor connection and make the electrical connection to the
terminals. Insert glass into luminaire base.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified electrician or a comparably qualified person using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. The defective glass must be replaced. Close the luminaire.
- Spares
- Spare glass 11 003 202 .0R G
- LED module 3000 K LED-0662/930
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com