BEGA 12127.2 Ceiling and Wall Luminaire for Indoor Use Instruction Manual

June 13, 2024
BEGA

BEGA-logo

BEGA 12127.2 Ceiling and Wall Luminaire for Indoor Use

Product Information

  • Product Description: Luminaire made of Aluminium, finish Colour white Hand-blown crystal glass, white inside, with screw-neck
  • Features:
    • Silicone gasket
    • Distance apart 190 mm
    • 2 cable entries for through-wiring for mains with plug connection
    • Earth conductor connection
    • 2-pole connecting terminal for LED power supply unit 220-240 V x 0/50-60 Hz DC 176-276 V
    • DALI-controllable
    • Number of DALI addresses: 1
    • Basic insulation is provided between the mains
    • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
    • Safety class I
    • Protection class IP 64 (Dust-tight and protection against splash water)
    • Impact strength IK06
    • Weight: 3.3 kg
  • Energy Efficiency Class: D
  • Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc., it is recommended to use separate overvoltage protection components.
  • Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
  • Lamp Module Information:
    • Module designation: LED-0854/930
    • Colour temperature: 3000 K
    • Colour rendering index: CRI > 90
    • Module luminous flux: 2255 lm
    • Luminaire luminous flux: 985 lm
    • Luminaire luminous efficiency: 61.6 lm/W

Product Usage Instructions

  1. Ensure that the luminaire is installed and operated according to national safety regulations.
  2. Installation and commissioning should be carried out by a qualified electrician.
  3. Do not modify the luminaire without proper authorization as it may void the warranty and cause safety hazards.
  4. For additional protection against overvoltage and transients, it is recommended to use separate overvoltage protection components.
  5. When connecting the luminaire to the mains, ensure that the earth conductor connection is properly made.
  6. The luminaire is equipped with a digital control system and can be controlled via DALI. Set the desired DALI address according to your requirements.
  7. The luminaire has a basic insulation between the mains and control lines for added safety.
  8. The luminaire features temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire.
  9. The luminaire has a safety class I rating and a protectionclass IP 64, making it dust-tight and protected against splash water.
  10. When replacing the lamp module, ensure that you use the correct module designation (LED-0854/930) with a colour temperature of 3000 K and a colour rendering index (CRI) of over 90.
  11. The module luminous flux is 2255 lm, while the luminaire luminous flux is 985 lm. The luminaire has a luminous efficiency of 61.6 lm/W.

Dimension

BEGA-12127.2-Ceiling-and-Wall-Luminaire-for-Indoor-Use-
FIG-1

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of aluminum and hand-blown crystal glass. For a variety of interior lighting applications.
Product description
Luminaire made of Aluminium, finish Colour white Hand-blown crystal glass, white inside, with screw-neck Silicone gasket 2 mounting holes ø 5.5 mm Distance apart 190 mm 2 cable entries for through-wiring for mains supply cable up to ø 10.5 mm max. 5 G 1.5@ Connecting terminal 2.5@ with plug connection Earth conductor connection 2-pole connecting terminal for digital control BEGA Ultimate Driver® LED power supply unit 220-240 V x 0/50-60 Hz DC 176-276 V DALI-controllable Number of DALI addresses: 1 Basic insulation is provided between the mains and control cables BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 64 Dust-tight and protection against splash water Impact strength IK06 Protection against mechanical  impacts < 1 jouler – Safety mark c – Conformity mark Weight: 3.3 kg This product contains light sources of energy efficiency class(es) D
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

  • Lamp
    • Module connected wattage 13.8 W
    • Luminaire connected wattage 16 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 45 °C
  • 12 127.2 K3
    • Module designation LED-0854/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 2255 lm
    • Luminaire luminous flux 985 lm
    • Luminaire luminous efficiency 61,6 lm / W

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Remove glass from luminaire housing by turning it counterclockwise. Disassemble LED module. Disconnect plug connection. Lead the mains supply cable through the cable entry into the luminaire housing. Fix luminaire housing with enclosed or any other suitable fixing material onto the mounting surface. It is absolutely essential to use the enclosed gaskets. Push silicone sleeves over the lines, make ground and electrical connection to the terminal–plug connection. For digital control please use the 2-pole plug connector (DALI). In case this connector is not used the luminaire will be operated at full light output. Push plug into coupler as far as it will go. Assemble LED module.  Screw glass with gasket firmly into the luminaire housing by turning it clockwise. Make sure that gasket is positioned correctly.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. The defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire.

  • Spares
    • Spare glass 11 003 081 47R G
    • LED power supply unit DEV-0312/500
    • LED module 3000 K LED-0854/930
    • Gasket glass 83 000 367

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com