BEGA 24361 Wall Washer Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 24361 Wall Washer
Dimension
Application
Wall washer with symmetrical light distribution for the illumination of
façades and wall surfaces with the mounting surface being the reflection
surface.
The luminaire can be installed with the light distribution opening upwards or
downwards.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite, silver or white
Clear safety glass
Silicone gasket
Reflector made of pure anodised aluminium
2 mounting holes ø 4.5mm
Distance apart 200mm
2 cable entries for through-wiring of mains supply cable ø 7-10.5mm, max.
5G1.5◻
Connecting terminal and
earth conductor terminal 2.5◻
LED power supply unit 220-240 V ≂0/50-60 Hz
DC 170-276 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical impacts < 2 joule
– Safety mark
– Conformity mark
Weight: 2.6 kg
This product contains light sources of energy efficiency class(es) D
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components. You can find them on our website
at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Lamp
Module connected wattage 32.7 W
Luminaire connected wattage 36.1 W
Rated temperature ta=25 °C
Ambient temperature ta max=25 °C
24 361K3
Module designation LED-0609/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 5540 lm
Luminaire luminous flux 4755 lm
Luminaire luminous efficiency 131,7 lm/W
24 361K4
Module designation LED-0609/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 5615 lm
Luminaire luminous flux 4819 lm
Luminaire luminous efficiency 133,5 lm/W
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo hexagon socket head screws (wrench size 3 mm) through the opening in the
luminaire housing up to the stop and lift luminaire top.
Disconnect plug connection.
Lead the mains supply cable through the cable entry of the luminaire base.
Ensure correct directionality towards the area to be illuminated.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Make the earth conductor connection and the electrical connection.
For digital control please use the connecting terminal DA, DA. In case this
terminal is not used the luminaire will be operated at full light output.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Make earth conductor connection between luminaire top and luminaire base. Push plug into coupler as far as it will go. Make sure that gasket is positioned correctly. Install the luminaire top, press-on and tighten screws evenly
Cleaning · Maintenance
Clean luminaire regularly with solvent-free
cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA
replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
LED power supply unit DEV-0391/700
LED module 3000 K LED-0609/830
LED module 4000 K LED-0609/840
Reflector 76 001 484
Gasket 83 001 508
Customers Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden ·
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>