BEGA 24 117 Ceiling and Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA 24 117 Ceiling and Wall Luminaire

BEGA-24-117-Ceiling-and-Wall-Luminaire-product

Product Information

The Decken- und Wandleuchte (Ceiling and wall luminaire) is a versatile lighting solution designed for both interior and exterior applications. It features a high protection class and can be installed on ceilings and walls. The luminaire is equipped with electronic components that are protected against overvoltage according to DIN EN 61547. Please note that additional overvoltage protection components are recommended for enhanced protection against transients.

Safety

Installation and operation of the luminaire must comply with national safety regulations. Only qualified electricians should carry out installation and commissioning. The manufacturer does not accept liability for damage caused by improper use or installation.
If any modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.

Installation

  1. Undo the hexagon socket head screw (wrench size 3 mm) in the luminaire base and remove the covering cap.
  2. Fix the luminaire base onto the mounting surface using the enclosed fixing material or any other suitable material.
  3. Note the position of application indicated by the luminaire top arrow pointing downwards.
  4. Place the luminaire top onto the luminaire base and tighten the screws evenly.

Product Specifications

Lamp| Module Connected Wattage| Luminaire Connected Wattage| Rated Temperature| Ambient Temperature
---|---|---|---|---
8x LED-0894/830 + 4x LED-0900/830| 44.4 W| 55 W| 25 °C| 40 °C
8x LED-0894/840 + 4x LED-0900/840| 44.4 W| 55 W| 24 117 K3| ta max = 25 °C, ta = 40 °C

Lighting Performance

Colour Temperature| Colour Rendering Index (CRI)| Module Luminous Flux| Luminaire Luminous Flux| Luminaire Luminous Efficiency
---|---|---|---|---
3000 K| CRI > 80| 9280 lm| 7500 lm| 136.4 lm/W
4000 K| CRI > 80| 9540 lm| 7710 lm| 140.2 lm/W

Please note: Do not remove the desiccant bag from the luminaire housing as it is needed to remove residual moisture.

Replacement Parts

  • Ersatzglas (Replacement Glass)
  • LED-Netzteil (LED Power Supply Unit)
  • LED-Modul 3000 K (LED Module 3000 K)
  • LED-Modul 4000 K (LED Module 4000 K)
  • Dichtung Glas (Glass Seal)

Dimension

Ceiling and wall luminaireBEGA-24-117-Ceiling-and-Wall-Luminaire-fig
1

Application

  • Unshielded ceiling and wall luminaire with high protection class.
  • For a variety of interior and exterior lighting applications.

Product description

  • Luminaire made of aluminium alloy,
  • aluminium and stainless steel
  • BEGA Unidure® coating technology
  • White synthetic diffuser
  • 2 elongated fixing holes
  • Width 7 mm · 1200 mm spacing
  • Connection box with 2 cable entries for through-wiring of the mains supply cable
  • ø 5-13 mm, max. 5×2,5@
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • During DC operation the LED power is reduced to 15 %
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK06
  • Protection against mechanical
  • impacts < 1 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 10.6 kg
  • This product contains light sources of energy efficiency class(es) B

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to  the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Installation

  • Undo the hexagon socket head screw (wrench size 3 mm) in the luminaire base and remove covering cap.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.BEGA-24-117-Ceiling-and-Wall-Luminaire-fig 4
  • Use the supplied connection box to make the electrical connection (see illustration).
  • Undo the hexagon socket screws and open the connection box.
  • Run the luminaire power supply cable through the PG 9 cable gland and the power connecting cable through the M25 cable gland and into the connection box. For through-wiring, the factory-fitted dummy plug must be removed.
  • Tighten the cable glands firmly.
  • Make the protective earth connection and the electrical connection.
  • Observe the correct configuration of the connecting cable. Make the mains connection to the brown (L), blue (N) and green-yellow wires ( ).
  • The control cables are connected via the two DALI-labelled wires white-red (wh-rd) and white-black (wh-bl). If these wires are not assigned, the luminaire will work with full light output.
  • Close the connection box. Make sure the gasket is properly located.
  • Note the position of application
  • of the luminaire top “arrow down”.
  • Place luminaire top onto theluminaire base and tighten screws evenly.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Lamp

  • Module connected wattage 44.4 W

  • Luminaire connected wattage 55 W

  • Rated temperature ta = 25 °C

  • Ambient temperature ta max = 40 °C
    24 117 K3

  • Module designation

  • 8x LED-0894/830 + 4x LED-0900/830

  • Colour temperature 3000 K

  • Colour rendering index CRI > 80

  • Module luminous flux 9280 lm

  • Luminaire luminous flux 7500 lm

  • Luminaire luminous efficiency 136,4 lm / W
    24 117 K4

  • Module designation

  • 8x LED-0894/840 + 4x LED-0900/840

  • Colour temperature 4000 K

  • Colour rendering index CRI > 80

  • Module luminous flux 9540 lm

  • Luminaire luminous flux 7710 lm

  • Luminaire luminous efficiency 140,2 lm / W

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacement Power supply unit / LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Undo the hexagon socket head screw
  • (wrench size 3) in the luminaire base and remove covering cap.
  • Loosen the three hexagon socket screws at the cover of connection compartment and lift off the cover of connection compartment. Loosen connecting cable at the plug-in terminals.
  • Disassemble front-end head plate at the terminal side. For this purpose loosen hexagon head screw (wrench size 4) as far as it will
  • go and remove head plate from the synthetic cover.
  • Pull out the LED module carrier out of the synthetic diffuser.
  • Replace power supply unit or LED module. Please follow the installation instructions for the LED module.
  • Insert LED module carrier.
  • Make sure that the module carrier is seated in the guiding bolts of the opposite head plate. Push head plate firmly on to the synthetic diffuser.
  • Make electrical connection at the plug-in terminals and assemble cover of connection compartment.
  • Place luminaire top onto the luminaire base and tighten screws evenly.

Spares

  • Spare glass 15 000 525 B3
  • LED power supply unit DEV-0159/1400
  • LED module 3000 K LED-0894/830
  • LED module 4000 K LED-0894/840
  • LED module 3000 K LED-0900/830
  • LED module 4000 K LED-0900/840
  • Gasket glass 83 001 761

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com