Application
Compact downlight with symmetrically focused wide beam light distribution. BEGA Ultradark Optics® offer a maximum of illumination and eye comfort due to a minimised diffuse light percentage and highly efficient glare suppression.

Product Description
Luminaire made of aluminum alloy, aluminum and stainless steel BEGA Unidure® coating technology Colour graphite or white Safety glass with optical structure Internal louvres and polymer lens BEGA Ultradark Optics® Louvres and the interior surface of the anti-glare ring with maximum light-absorbing ultra-black nano-coating 2 mounting holes ø 4.8 mm Distance apart 160 mm 2 cable entries for through-wiring of mains supply cable ø 7-12 mm, max. 5 x 2,5@ Connection terminal 2.5@ Earth conductor connection BEGA Ultimate Driver® LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V DALI-controllable Number of DALI addresses: 1 Basic insulation is provided between the mains and control cables BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 65 Dust-tight and protection against water jets Impact strength IK07 Protection against mechanical impacts < 2 joule r – Safety mark c  – Conformity mark Weight: 2.8 kg This product contains light sources of energy efficiency class(es) D

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Module connected wattage 40.3 W
  • Luminaire connected wattage 44 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

24 752 K3

  • Module designation LED-1263/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6010 lm
  • Luminaire luminous flux 4185 lm
  • Luminaire luminous efficiency 95,1 lm / W

24 752 K4

  • Module designation LED-1263/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6190 lm
  • Luminaire luminous flux 4310 lm
  • Luminaire luminous efficiency 98 lm / W

Lighting technology
Half beam angle 25°

Please note:
Contact with the inner surface of the luminaire reflector should be avoided in order to permanently protect the special stray lightminimising properties of the nano-coating.

Installation

Pass the power connecting cable through the cable entry in the mounting plate. Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface. Be sure to use the gasket rings supplied. Make the earth conductor connection and the electrical connection. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Make earth conductor connection between luminaire housing and mounting plate.
Push plug into coupler as far as it will go. Make sure that gasket is positioned correctly. Insert the luminaire housing into the mounting plate and turn it as far as it will go.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system. LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during relamping. Remove luminaire housing from mounting plate by turning it counter-clockwise. Disconnect the plug-in devices. Undo retaining screw (wrench size 2.5 mm) in the luminaire housing. Remove the trim ring along with the glass and reflector from the luminaire housing by turning it counter-clockwise. Replace LED module. Please follow the installation instructions for the LED module. Screw the trim ring along with the glass and reflector into the luminaire housing by turning it clockwise. Tighten retaining screw in the luminaire housing firmly. Make earth conductor connection between luminaire housing and mounting plate. Push plug into coupler as far as it will go. Make sure that gasket is positioned correctly. Insert the luminaire housing into the mounting plate and turn it as far as it will go.

Spares

  • LED power supply unit DEV-0270/1050i
  • LED module 3000 K LED-1263/830
  • LED module 4000 K LED-1263/840
  • Gasket 83 002 048

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com