BEGA 51260.1 Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA logo 51 260.1
Technical amendments reserved
Wall luminaire for indoor use
Instruction Manual

51260.1 Wall Luminaire

BEGA 51260.1 Wall Luminaire Instructions for use

Application

Wall luminaire · indoor luminaire with light emission on one side for the glare free illumination of wall surfaces with the mounting surface being the reflection surface.
A luminaire which allows interesting illumination concepts individually or in rows.

Product description

Luminaire housing made of aluminium, finish colour velvet white
Silicone light diffuser 3 elongated fixing holes
Width 4.5 mm · 895 mm spacing
Mounting plate with several openings for cable entry and through-wiring for mains cable
Connecting terminals 2.5@
Earth conductor connection
LED power supply unit 220-240 V x 0/50-60 Hz
DC 176-276 V
During DC operation the LED power is reduced to 15 %
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Impact strength IK08
Protection against mechanical impacts < 5 joule
**** – Conformity mark
Weight: 5.0 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 34.7 W
Luminaire connected wattage 38.5 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 55 °C

51 260.1 K3

Module designation LED-1321/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 5400 lm
Luminaire luminous flux 3430 lm
Luminaire luminous efficiency 89,1 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the hexagon socket head screws (wrench size 3 mm) and lift luminaire housing.
Loosen earth connection (plug connection) between luminaire housing and mounting plate.
Pass the power connecting cable through one of the openings of the mounting plate.
Ensure correct directionality towards the area to be illuminated.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Make the electrical connection to the terminals.
Please ensure correct wire assignment for the connecting cable.
Connect the earth conductor to the greenyellow wire ( ****). Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
Use the terminals marked DA, DA for digital control.
If these terminals are not used, the luminaire will operate at full light output.
Make earth connection (plug connection) between luminaire housing and mounting plate again.
Hang the luminaire housing in the mounting plate and screw it in place with the hexagon socket head screws.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective luminaire cover must be replaced.
Close the luminaire.

Spares

LED power supply unit DEV-0159/700i
LED module 3000 K with diffusor LED-1321/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com