DIMENSIONS

Application

Pendant luminaire with symmetrical flat beam light distribution for use with catenary systems. Their light distribution is especially suitable for illuminating streets according to DIN EN 13 201.
The cable hanger system of the luminaire is suitable for transverse suspension systems and longitudinal chain systems.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology Safety glass, antireflection-coated Silicone gasket Reflector made of pure anodised aluminium Cable hanger for tension cable of ø 5mm to ø 12mm with suspending bracket and cable clamp Thrust screws M8 and lock nuts are made of stainless steel – grade No 1.4301 Horizontal infinitely adjustable ± 5° Vertical infinitely adjustable 360° Connection box with cable entries for through wiring of mains supply cable ø 10-14mm max. 5 × 2,5@ BEGA Ultimate Driver® LED power supply unit 220-240 V 0/50-60 Hz DC 176-264 V DALI- controllable Number of DALI addresses: 2 Basic insulation is provided between the mains and control cables BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 66 Dust-tight and protection against strong water jets Impact strength IK08 Protection against mechanical impacts < 5 joule
– Safety mark
 – Conformity mark
Wind catching area: 0.065 m²
Weight: 8.4 kg
This product contains light sources of energy efficiency class(es) C

Dark Sky

The light of this luminaire is directed evenly and highly efficiently onto the surface to be illuminated. No light is emitted into the upper half-space of the luminaire.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

Module connected wattage 62 W
Luminaire connected wattage 69 W
Rated temperature ta=25 °C
Ambient temperature ta max=55 °C

99 460K4

Module designation 4x LED-0364/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 12380 lm
Luminaire luminous flux 10260 lm
Luminaire luminous efficiency 148,7 lm/W

99 460K3

Module designation 4x LED-0364/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 12020 lm
Luminaire luminous flux 9962 lm
Luminaire luminous efficiency 144,4 lm/W

Installation

Place cable hanger with luminaire onto the tension cable. Align unit axially.
Make tight connection between cable clamp with thrust screws M8 and tension cable.
Secure thrust screw with lock nut.
For through-wiring of the mains supply cable the dummy screw gland must be replaced with enclosed screw cable gland.
Open the connection box and lead free line ends into connection box.
Make earth conductor connection und electrical connection to connecting terminal. For digital control please use the connecting terminal DA, DA.
In case this connector is not used the luminaire will be operated at full light output.
Tighten screw cable glands firmly.
When no through wiring is done, one screw cable gland must be closed with the enclosed dummy plug. Close the connection box. Make sure that the gasket is positioned correctly.
Tighten screws evenly.
In case the supporting cable is not stretched in a horizontal position it is possible to bring the luminaire in a horizontal burning position by adjusting the screw joint at the junction box. Adjustable range ± 5°.

Please note

Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced. Close the luminaire.

Spares

LED power supply unit DEV-0270/700
LED module 3000 K LED-0364/830
LED module 4000 K LED-0364/840
Reflector 76 001 172
Gasket housing 83 001 401
Gasket connection box 83 002 00