BEGA 51132 Wall Luminaire Instruction Manual

June 13, 2024
BEGA

51132 Wall Luminaire
Instruction Manual
Wall luminaire for indoor use

BEGA 51132 Wall Luminaire

Instructions for use

Application

Closed and unshielded wall luminaire · Indoor luminaire made of hand-blown opal glass, satin matt and with metal fitting.
Due to the soft and flowing shape of the glass, you can create seemingly random wall arrangements with other luminaires in this series.
The luminaire glass can be rotated on the fitting.

Product description

Metal luminaire mounting plate, finish Colour white
Lichtenstein ® · PEBBLES · Type B
Hand-blown opal glass, satin matt 2 mounting holes ø 5.5 mm
Distance apart 230 mm 2 cable entries for through-wiring for connection cable up to ø 10,5 mm max. 5 x 1.5@
Connection terminal 2.5@ Earth conductor connection
LED power supply unit 220-240 V x 0/50-60 Hz
DALI-controllable
Number of DALI addresses: 0
Basic insulation is provided between the mains and control cables BEGA Thermal Control® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Impact strength IK04 Protection against mechanical impacts < 0.5 joule
Conformity mark
Weight: 3.7 kg
This product contains light sources of energy efficiency class(es) D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for
these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection againste. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

Module connected wattage 26.4 W
Luminaire connected wattage 30 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 50 °C

51 132 K27

Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 3845 lm
Luminaire luminous flux 2558 lm
Luminaire luminous efficiency 85,3 lm / W

51 132 K3

Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 3970 lm
Luminaire luminous flux 2642 lm
Luminaire luminous efficiency 88,1 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Lead the mains supply cable through the cable entry into the luminaire housing.
Secure the luminaire fitting to the installation surface with the fixing materials provided or other suitable materials.
Be sure to use the gasket rings supplied.
Establish earth conductor connection and make the electrical connection to the terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.

BEGA 51132 Wall Luminaire - fig1Position the glass over the luminaire fitting so that the retaining spring fits into the recess in the raised edge of the glass.
Press the glass against the retaining spring at a flat angle as far as it will go and push it into the luminaire fitting (see drawing).
Gentle pressure on the glass will fix it in the luminaire fitting through the two lobes on the opposite side.

BEGA 51132 Wall Luminaire - fig1 IMPORTANT : Screw the grub screw (hexagon socket head wrench size 2,5) with gentle pressure against the retaining spring.
In this way, the glass is held securely in place and is resistant to vibration.
If the orientation of the rotatable luminaire glass on the fitting is to be changed, the grub screw must be loosened. After adjusting the glass, screw the grub screw with gentle pressure against the retaining spring.

Opening the luminaire
Unscrew the grub screw (Allen screw) of the glass retaining spring of the luminaire fitting as far as it will go.
The luminaire glass must be pressed against the spring pressure of the glass retaining spring in order to release it from the luminaire fitting.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Replace the LED unit.
Close the luminaire.
A damaged glass must be replaced.

Spares

Spare glass 11 003 619 .0R G
LED spare assembly unit 2700 K 75 005 453 K27
LED spare assembly unit 3000 K 75 005 453 K3

BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 · 58689 Menden ·
info@bega.com ·
www.bega.com

Documents / Resources

| BEGA 51132 Wall Luminaire [pdf] Instruction Manual
51132 Wall Luminaire, 51132, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals