BEGA 51132 Wall Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
51132 Wall Luminaire
Instruction Manual
Wall luminaire for indoor use
Instructions for use
Application
Closed and unshielded wall luminaire · Indoor luminaire made of hand-blown
opal glass, satin matt and with metal fitting.
Due to the soft and flowing shape of the glass, you can create seemingly
random wall arrangements with other luminaires in this series.
The luminaire glass can be rotated on the fitting.
Product description
Metal luminaire mounting plate, finish Colour white
Lichtenstein ® · PEBBLES · Type B
Hand-blown opal glass, satin matt 2 mounting holes ø 5.5 mm
Distance apart 230 mm 2 cable entries for through-wiring for connection cable
up to ø 10,5 mm max. 5 x 1.5@
Connection terminal 2.5@ Earth conductor connection
LED power supply unit 220-240 V x 0/50-60 Hz
DALI-controllable
Number of DALI addresses: 0
Basic insulation is provided between the mains and control cables BEGA Thermal
Control® Temporary thermal regulation to protect temperature-sensitive
components without switching off the luminaire Safety class I Impact strength
IK04 Protection against mechanical impacts < 0.5 joule
Conformity mark
Weight: 3.7 kg
This product contains light sources of energy efficiency class(es) D, E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for
these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection againste. g. transients, etc. we recommend
separate overvoltage protection components. You can find them on our website
at www.bega.com.
Lamp
Module connected wattage | 26.4 W |
---|---|
Luminaire connected wattage | 30 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 50 °C |
51 132 K27
Colour temperature | 2700 K |
---|---|
Colour rendering index | CRI > 90 |
Module luminous flux | 3845 lm |
Luminaire luminous flux | 2558 lm |
Luminaire luminous efficiency | 85,3 lm / W |
51 132 K3
Colour temperature | 3000 K |
---|---|
Colour rendering index | CRI > 90 |
Module luminous flux | 3970 lm |
Luminaire luminous flux | 2642 lm |
Luminaire luminous efficiency | 88,1 lm / W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Lead the mains supply cable through the cable entry into the luminaire
housing.
Secure the luminaire fitting to the installation surface with the fixing
materials provided or other suitable materials.
Be sure to use the gasket rings supplied.
Establish earth conductor connection and make the electrical connection to the
terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Position the glass
over the luminaire fitting so that the retaining spring fits into the recess
in the raised edge of the glass.
Press the glass against the retaining spring at a flat angle as far as it will
go and push it into the luminaire fitting (see drawing).
Gentle pressure on the glass will fix it in the luminaire fitting through the
two lobes on the opposite side.
IMPORTANT :
Screw the grub screw (hexagon socket head wrench size 2,5) with gentle
pressure against the retaining spring.
In this way, the glass is held securely in place and is resistant to
vibration.
If the orientation of the rotatable luminaire glass on the fitting is to be
changed, the grub screw must be loosened. After adjusting the glass, screw the
grub screw with gentle pressure against the retaining spring.
Opening the luminaire
Unscrew the grub screw (Allen screw) of the glass retaining spring of the
luminaire fitting as far as it will go.
The luminaire glass must be pressed against the spring pressure of the glass
retaining spring in order to release it from the luminaire fitting.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to
those of the LED units originally fitted. The LED unit can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Replace the LED unit.
Close the luminaire.
A damaged glass must be replaced.
Spares
Spare glass | 11 003 619 .0R G |
---|---|
LED spare assembly unit 2700 K | 75 005 453 K27 |
LED spare assembly unit 3000 K | 75 005 453 K3 |
BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 · 58689 Menden ·
info@bega.com ·
www.bega.com
Documents / Resources
| BEGA
51132 Wall
Luminaire
[pdf] Instruction Manual
51132 Wall Luminaire, 51132, Wall Luminaire, Luminaire
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>