Application
Shielded wall luminaire · indoor luminaire for many lighting tasks in interior
applications.
The light emits upwards and downwards.
Product description
Aluminium alloy housing, finish Colour white Crystal glass, inside white 2
elongated fixing holes Width 4.5 mm · 176 mm spacing 2 cable entries for
through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
Connection terminal 2.5@ Earth conductor connection LED power supply unit
220-240 x 0/50-60 Hz DC 170-280 V Safety class I
Safety mark
Conformity mark
Weight: 1.1 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 8.2 W |
---|---|
Luminaire connected wattage | 10.5 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 40 °C |
12 277.1 K3
Module designation | LED-0598/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1205 lm |
Luminaire luminous flux | 674 lm |
Luminaire luminous efficiency | 64,2 lm / W |
Installation
Undo set screws and lift off luminaire housing.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Loosen earth connection (plug connection) and LED-connection between luminaire
housing and mounting plate.
Lead the mains supply cable through the cable entry of the mounting plate.
Note position of application “arrow down”.
Fix mounting plate with enclosed or any other suitable fixing material onto
the mounting surface.
It is imperative to use the enclosed gaskets.
Make earth connection.
Pull silicone sleeves over the wires and make electrical connection to the
terminals.
Make earth connection (plug connection) and LED-connection between luminaire
housing and mounting plate again.
Install luminaire onto the mounting plate and tighten set screws evenly.
Note position of application “arrow down”.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED module
he designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
LED power supply unit | DEV-0141/350 |
---|---|
LED module 3000 K | LED-0598/930 |
BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
Documents / Resources
| BEGA
12277.1 Wall
Luminaire
[pdf] Instructions
12277.1 Wall Luminaire, 12277.1, Wall Luminaire, Luminaire
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>