BEGA 50185.6 Ceiling Luminaire Instruction Manual

June 13, 2024
BEGA

50185.6 Ceiling Luminaire
**Instruction Manual
Ceiling luminaire for indoor use

BEGA 50185.6 Ceiling Luminaire**

Instructions for use

Application

Ceiling luminaire · indoor luminaire with aluminium housing for non-glare light deflected downwards.
The used LED technique offers durability and optimal light output with low power consumption at the same time.

Product description

Ceiling luminaire »STUDIO LINE« Aluminium housing shield,
Finish Colour velvet black inside hue matt copper
Light-diffusing silicone lens
Mounting plate with 2 fixing holes ø 4.5 mm · 80 mm spacing Connecting terminals 2.5@
Earth conductor connection
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-280 V
Safety class I
Safety mark
Conformity mark
Weight: 0.6 kg
This product contains light sources of energy efficiency class(es) D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

Module connected wattage 8.9 W
Luminaire connected wattage 10.6 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C

50 185.6 K3

Module designation LED-0623/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 1135 lm
Luminaire luminous flux * 314 lm
Luminaire luminous efficiency * 29,6 lm / W
  • preliminary data

Lighting technology

Luminaire data for the DIALux lighting design program for outdoor lighting, street lighting and indoor lighting, as well as luminaire data in EULUMDAT and IES format are available on the BEGA website at www.bega.com.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Pull off LED cover from mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Make the earth conductor connection and the electrical connection to the terminals.
Clip LED cover onto mounting plate.
Pass the enclosed housing shield over the LED cover until the housing shield latches in place audibly.

BEGA 50185.6 Ceiling Luminaire - fig1

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Pull housing shield off the mounting plate.
Open the luminaire.
Please follow the installation instructions for the LED module. Close the luminaire.
Pass the housing shield over the LED cover until the housing shield latches in place audibly.

Spares

Shield 42 000 207 L1
LED power supply unit DEV-0136/500
LED module 3000 K LED-0623/830
LED module 3000 K LED-0623/930

BEGA Gantenbrink-Leuchten KG
Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 50185.6 Ceiling Luminaire [pdf] Instruction Manual
50185.6 Ceiling Luminaire, 50185.6, Ceiling Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals