Wall luminaire for indoor use
50 755.2

50755.2 LED Wall Luminaire

BEGA 50755 2 LED Wall Luminaire - indoor use

Application

Wall luminaire · indoor luminaire with velvet black luminaire housing and inside hue.
Luminaire with shielded light source for illumination of wall surfaces with the mounting surface being the reflection surface. The light emits upwards and downwards.

Product description

Wall luminaire “STUDIO LINE”
Luminaire housing made of aluminium, surface Colour velvet black inside hue aluminium matt
Light-diffusing synthetic LED cover 2 elongated fixing holes
Width 4.5 mm · 210 mm spacing 1 cable entry for through-wiring for mains cable
Connection terminal 2.5◻
Earth conductor connection
LED power supply unit 220-240 V ≂ 0/50-60 Hz
DC 176-280 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
– Safety mark
****– Conformity mark
Weight: 0.9 kg
This product contains light sources of energy efficiency class(es) D

Lamp

Module connected wattage 11.8 W
Luminaire connected wattage 13.7 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 55 °C

50 755.2 K3

Module designation LED-0393/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 1840 lm
Luminaire luminous flux 821 lm
Luminaire luminous efficiency 59,9 lm / W

**Safety

**

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Installation

Undo the hexagon socket head screws (wrench size 2.5 mm) and lift luminaire housing.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Loosen earth connection (plug connection) and LED-connection (plug – plug socket) between luminaire housing and mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Make sure to use the gaskets supplied.
Establish earth conductor connection and make the electrical connection to the terminals.
Restore the earth conductor connection (plug contact) and LED connection (plug– jack) between the luminaire housing and the mounting plate.
Install luminaire housing onto the mounting plate and tighten hexagon socket head screws evenly.
Carefully insert the supplied shield into the luminaire housing. Make sure that in its final position, the shield engages with its magnetic underside flush to the profile groove of the luminaire housing.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified personnel using standard tools.
Disconnect the system from the mains.
Undo the hexagon socket head screws (wrench size 2.5 mm) and lift luminaire housing.
Loosen earth connection (plug connection) and LED-connection (plug – plug socket) between luminaire housing and mounting plate.
In order to loosen the screw connection of the LED module, first loosen the hexagon nuts on the inside and remove the metal plate from the luminaire housing. Remove the loose luminaire cover.
Press the synthetic LED cover together lengthwise and remove it from the housing profile.
Remove the LED module. Install the replacement LED module.
Please follow the installation instructions for the LED module.
A defective LED cover must be replaced.
Install the luminaire again in the reverse order.

Spares

Synthetic cover 15 000 601 B1
LED power supply unit DEV-0136/700
LED module 3000 K LED-0393/930
Shield 72 003 359 B1

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 50755.2 LED Wall Luminaire [pdf] Instruction Manual
50755.2 LED Wall Luminaire, 50755.2, LED Wall Luminaire, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals