Recessed ceiling luminaire for indoor use
50 876.2

50876.2 Recessed Ceiling Luminaire

BEGA 50876 2 Recessed Ceiling Luminaire - indoor use

Instructions for use

Application

Free-radiating recessed ceiling luminaire · indoor luminaire with crystal glass and aluminium alloy housing for connection to external LED power supply unit.
For surface-mounted installation in indoor suspended ceilings of 5-25 mm thickness.

Product description

Recessed luminaire without power supply unit
Luminaire housing made of cast aluminium
Installation housing is made of glass-fibre reinforced polyamide with 2 fastening springs
Crystal glass with bayonet closure
Synthetic lens with light-diffusing white matt finish
Ceiling trim ring made of metal, Stainless steel
Ceiling aperture ø 146 mm
Free space installation depth required 105 mm 1 connecting cable with strain relief and plug connector system for BEGA power supply unit, on/off or DALI
Safety class III
****– Conformity mark
Weight: 1.4 kg
This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 11.5 W
Luminaire connected wattage 13.5 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C
When installed in heat-insulating material  ta max = 25 °C

50 876.2 K3

Module designation LED-0800/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 1735 lm
Luminaire luminous flux 1056 lm
Luminaire luminous efficiency 78,2 lm / W

**Installation

**

A separate power supply unit is required to operate the luminaire.
For connection to external LED-power supply unit – accessory 13 144 or 13 169 – the luminaire is equipped with a 2-pin connector.
Note operating instructions of the LED-power supply units.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the installation housing in the recessed opening is achieved by using two adjustable springs.
Installation into inserted ceilings:

A recessed opening of 146 mm is necessary to accept the installation housing. Recessed depth min. 105 mm.
Compress the fastening springs of the installation housing against their spring pressure on both sides towards the housing and slide the installation housing into the recessed opening.
The fastening springs catch the ceiling panel from the back side. Minimum thickness of the ceiling panel is 5 mm. If minimum thickness of the panel is less than 5 mm it must be reinforced from the reverse side. Maximum thickness of the ceiling panel must be no more than 25 mm.

BEGA 50876 2 Recessed Ceiling Luminaire - ceiling
panel

Push the enclosed threaded rods through the two inside openings of the installation housing and guide the clamping angle of the threaded rods downwards onto the suspended ceiling. Clip the threaded rods into their guide grooves and screw them in by hand as far as possible. Fix in end position with screwdriver (TX 10). This clamp fixing prevents the installation housing from turning and dropping.
Connect to the LED power supply unit.
Route the LED power supply unit through the installation housing and place it in the suspended ceiling.
Connect the 2-pin plug connector between luminaire and external LED power supply unit.

BEGA 50876 2 Recessed Ceiling Luminaire - supply unit

Press together the two internal fixing sliders inside the luminaire housing.
Push the luminaire housing to the end of the installation housing and then release the fixing sliders.
This mechanism ensures that the luminaire housing sits securely inside the installation housing.
Fix crystal glass with cover ring and dispersing lens into the luminaire housing by turning it clockwise.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Please follow the installation instructions for the LED module.
Screw in glass by turning it clockwise.
Defective glass must be replaced.

Accessories

Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.

13 144 Power supply unit on/off
13 169 Power supply unit DALI

The power supply units are only suitable for the operation of one LED luminaire.
For the accessories a separate instructions for use can be provided upon request.

Spares

LED module 3000 K LED-0800/930
Spare glass 75 003 976

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com 
www.bega.com

Documents / Resources

| BEGA 50876.2 Recessed Ceiling Luminaire [pdf] Instruction Manual
50876.2 Recessed Ceiling Luminaire, 50876.2, Recessed Ceiling Luminaire, Ceiling Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals