BEGA 67684.1 Wall Luminaire for Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 67684.1 Wall Luminaire for Indoor Use
Product Information
The product is a luminaire that requires installation and operation in
accordance with national safety regulations. It is recommended to have a
qualified electrician perform theinstallation and commissioning. The
manufacturer does not assume liability for damage caused by improper use or
installation. Any modifications made to the luminaire should be done by the
person responsible for these modifications, who will be considered the
manufacturer.
The luminaire has electronic components that are protected against overvoltage
according to DIN EN 61547. Additionalovervoltage protection components are
recommended for enhanced protection against transients. These components can
be found on the manufacturer’s website at www.bega.com.
The product is available in different module designations, each with its own characteristics:
-
Module Designation: 2x LED-0546/927
-
Colour Temperature: 2700 K
-
Colour Rendering Index (CRI): > 90
-
Module Luminous Flux: 2450 lm
-
Luminaire Luminous Flux: 1649 lm
-
Luminaire Luminous Efficiency: 84.6 lm / W
-
Module Designation: 2x LED-0551/927
-
Colour Temperature: 2700 K
-
Colour Rendering Index (CRI): > 90
-
Module Luminous Flux: 2450 lm
-
Luminaire Luminous Flux: 1649 lm
-
Luminaire Luminous Efficiency: 84.6 lm / W
-
Module Designation: 2x LED-0546/930
-
Colour Temperature: 3000 K
-
Colour Rendering Index (CRI): > 90
-
Module Luminous Flux: 2530 lm
-
Luminaire Luminous Flux: 1703 lm
-
Luminaire Luminous Efficiency: 87.3 lm / W
-
Module Designation: 2x LED-0551/930
-
Colour Temperature: 3000 K
-
Colour Rendering Index (CRI): > 90
-
Module Luminous Flux: 2530 lm
-
Luminaire Luminous Flux: 1703 lm
-
Luminaire Luminous Efficiency: 87.3 lm / W
Product Usage Instructions
To replace the LED module:
- Locate the designation of the LED module on the label inside the luminaire.
- Disconnect the system and open the luminaire.
- Follow the installation instructions provided for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- If the glass is defective, it must be replaced.
- Close the luminaire after completing the replacement.
Regularly clean the luminaire with solvent-free cleansers to remove dirt.
Replacement Parts
- Replacement Glass
- LED Power Supply
- LED Module 2700 K
- LED Module 3000 K
- Gasket
Dimension
Instructions for use
Application
Wall luminaire · indoor luminaire made of handblown opal glass, satin matt and
metal housing. For all lighting tasks in interior applications. Luminaire with
a high protection class.
Product description
Die-cast aluminum and aluminium housing, finish Colour white Hand-blown opal
glass, satin matt Silicone gasket 2 mounting holes ø 5.5 mm Distance apart 540
x 56 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm,
max. 5 G 1.5@ Connection terminal 2.5@ Earth conductor connection 2-pole
connecting terminal for digital control LED power supply unit 220-240 V x
0/50-60 Hz DC 176-264 V DALI-controllable Basic insulation is provided between
the mains and control cables BEGA Thermal Switch® Temporary thermal shutdown
to protect temperature-sensitive components Safety class I Protection class IP
44 Protected against granular foreign bodies ≥ 1 mm and splash water impact
strength IK02 Protection against mechanical impacts < 0.2 joule r – Safety
markc – Conformity mark Weight: 2.8 kg This product contains light sources of
energy efficiency classes D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve additional protection
against e. g. transients, etc. we recommend separate overvoltage protection
components. You can find them on our website at
www.bega.com.
- Lamp
- Module connected wattage 16.6 W
- Luminaire connected wattage 19.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
- 67 684.1 K27
- Module designation
- 2x LED-0546/927 2x LED-0551/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 2450 lm
- Luminaire luminous flux 1649 lm
- Luminaire luminous efficiency 84,6 lm / W
- 67 684.1 K3
- Module designation
- 2x LED-0546/927 2x LED-0551/927
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 2530 lm
- Luminaire luminous flux 1703 lm
- Luminaire luminous efficiency 87,3 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping. Loosen
screw of the lateral cover and take off the glass from the luminaire housing.
Lead the mains supply cable through the cable entry into the luminaire
housing. Fix luminaire housing with enclosed or any other suitable fixing
material on to the mounting surface. It is absolutely essential to use the
enclosed gaskets. Make earth conductor connection. Push silicone sleeves over
the lines and make electrical connection. For digital control please use the
connecting terminal DA, DA. In case this terminal is not used the luminaire
will be operated at full light output. Position glass into the base plate and
fix it with the screw and the cover.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Inspect and,
if necessary, replace the luminaire gaskets. The defective glass must be
replaced. Close the luminaire.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Spares
- Spare glass 11 002 830 .0R G
- LED power supply unit DEV-0388/370
- LED module 2700 K LED-0551/927
- LED module 3000 K LED-0551/930
- LED module 2700 K LED-0546/927
- LED module 3000 K LED-0546/930
- Gasket glass 81 000 277 .3
- Gasket 83 001 249
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>