BEGA 24 816 Surface Washer Instruction Manual

June 12, 2024
BEGA

BEGA 24 816 Surface Washer

BEGA-24-816-Surface-Washer-product

Product Information

The product is a surface washer with asymmetrical light distribution designed for in-depth illumination of surfaces. It can be used to light ceiling, wall, and ground surfaces. The asymmetrical light distribution is especially suitable for spatial illumination.

Safety

Installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out installation and commissioning. The manufacturer is not liable for damage caused by improper use or installation. Any modifications to the luminaire should be done by the person responsible for them.

Overvoltage Protection

The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients and other factors, separate overvoltage protection components are recommended. These can be found on the manufacturer’s website at www.bega.com.

Dimensions

BEGA-24-816-Surface-Washer-fig-1

Application

  • Surface washer with asymmetrical light distribution for in-depth illumination of surfaces.
  • For lighting ceiling, wall and ground surfaces.
  • The asymmetrical light distribution is particularly suitable for the spatial illumination of surfaces.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Clear safety glass
  • Reflector made of pure anodised aluminium
  • Swivel range around the horizontal axis +90 ° to -30 ° in increments of 10°
  • Mounting plate with 3 fixing holes ø 5.5 mm
  • Angle 120° · Pitch circle ø 85 mm
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class: I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK10
  • Protection against mechanical impacts < 20 joule
  • Safety mark
  • CE: Conformity mark
  • Weight: 5.2 kg
  • This product contains light sources of energy efficiency class(es) C

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Specification

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage: 54.2 W
  • Luminaire connected wattage: 58.5 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 40 °C

24 816 K4

  • Module designation: LED-0773/840
  • Colour temperature: 4000 K
  • Colour rendering index: CRI > 80
  • Module luminous flux: 9575 lm
  • Luminaire luminous flux: 7160 lm
  • Luminaire luminous efficiency: 122,4 lm / W

24 816 K3

  • Module designation: LED-0773/830
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 80
  • Module luminous flux: 9440 lm
  • Luminaire luminous flux: 7059 lm
  • Luminaire luminous efficiency: 120,7 lm / W

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Maintenance

Cleaning /Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • LED power supply unit: DEV-0356/1050
  • LED module 3000 K: LED-0773/830
  • LED module 4000 K: LED-0773/840
  • Reflector: 76 001 373
  • Gasket glass frame: 83 000 924
  • Gasket mounting box: 83 001 838

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)