BEGA 50654.1 Ceiling and Wall Luminaire for Indoor Use Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 50654.1 Ceiling and Wall Luminaire for Indoor Use
Dimension
Instructions for Use
Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass,
satin matt and metal housing, for all lighting tasks.
They are ideal for places where a soft and uniform lighting distribution is
required.
Product Description
Metal housing, finish Colour white
Hand-blown opal glass, satin matt,
with sliding-bolt closure
2 mounting holes ø 5.5mm
Distance apart 240mm
2 cable entries for through-wiring for mains
cable up to ø 10.5 mm max. 3 × 1.5@
Connecting terminal 2.5@
with plug connection
Earth conductor connection
LED power supply unit
220-240 V x 0/50-60 Hz
DC 170-280 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect
temperature-sensitive components
Safety class I
Protection class IP 44
Protected against granular foreign bodies
≥ 1 mm and splash water
Impact strength IK07
Protection against mechanical
impacts < 2 joule
Safety mark
Conformity mark
Weight: 4.4 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage Protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage 25.3 W
Luminaire connected wattage 29 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C
50 654.1K3
Module designation LED-0570/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 3615 lm
Luminaire luminous flux 1928 lm
Luminaire luminous efficiency 66,5 lm/W
- preliminary data
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Disassemble LED module.
Loosen LED-connection and earth connection (plug connection).
Dismantle the mains supply cable max. 80 mm.
Lead mains supply cable through the cable entry into the luminaire housing.
Fix the luminaire housing with enclosed or any other suitable fixing material
onto the mounting surface.
It is imperative to use the enclosed gaskets.
Make earth and electrical connection to the terminal.
Make earth connection between LED module and luminaire housing (plug
connection).
Push LED-plugs into couplers as far as it will go.
Assemble LED module.
Tighten the screws evenly (max. 0,8 Nm).
Please observe that the LED module is not damaged mechanically.
Insert the opal glass into the luminaire housing with sliding bolt glass
closure and turn the glass clockwise up to the stop.
Place glass to the luminaire housing and observe that the holding spring bolts
fit into the notches of the glass.
Turn the glass clockwise until it is locked.
Thus, you reach a safe and vibration-resistant holding of the glass.
To release the glass from the luminaire housing, turn it counter-clockwise.
Replacement of the LED module · Maintenance
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Clean glass and luminaire regularly with solvent-free cleansers from dirt.
Please follow the installation instructions for the LED module.
Screw in glass by turning it clockwise as far as it will go.
A broken glass must be replaced.
Spares
Spare glass 11 002 771 .0RG
LED power supply unit DEV-0291/850
LED module 3000 K LED-0570/930
Customer Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>