BEGA 50523.1 Recessed Ceiling and Wall Luminaire for Indoor Use
Dimension
Application
Recessed ceiling and wall luminaire · indoor luminaire with hand-blown opal
glass, satin matt and aluminium housing for connection to an external LED
power supply unit.
For installation into ceilings with a shallow depth in interior areas.
Product description
LED recessed luminaire without power supply unit
Luminaire housing made of aluminium
Metal cover ring
Finish Colour white
Opal glass, satin matt, with screw neck
Silicone gasket
Recessed opening ø 166mm
Required installation depth 65mm
Luminaire housing with 3 fixing claws and guide screws
1 connecting cable with strain relief and plug connector system for BEGA power
supply unit, on/off or DALI
Safety class
– Conformity mark
Weight: 0.95 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components. You can find them on our website
at www.bega.com.
Lamp
Module connected wattage: 8.3 W
Luminaire connected wattage: 11 W
Rated temperature: ta=25 °C
Ambient temperature: ta max=50 °C
When installed in heat-insulating material: ta max=25 °C
50 523.1K3
Module designation: LED-0445/930
Colour temperature: 3000 K
Colour rendering index : CRI >90
Module luminous flux: 1355 lm
Luminaire luminous flux: 570 lm
Luminaire luminous efficiency: 51,8 lm/W
50 523.1K4
Module designation : LED-0445/940
Colour temperature : 4000 K
Colour rendering index: CRI >90
Module luminous flux : 1430 lm
Luminaire luminous flux : 602 lm
Luminaire luminous efficiency: 54,7 lm/W
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
A separate power supply unit is required to operate the luminaire – accessory 13 176 or 13 172.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using three adjustable
wedgeshaped claws.
Installation in solid walls or ceilings
To accommodate the luminaire and the external power supply unit we recommend using the installation housing 13 027.
Please note:
To ensure that the luminaire is securely held in the plastered installation housing, it is essential to unscrew the screws on the underside of the fastening claws and remove the adapter for the fastening claws (see drawing).
Installation in suspended ceilings
A recessed opening of ø 166 mm with a minimum installation depth of 65 mm is
required.
The lateral distance between the luminaire housing and parts of the building
must be at least 50 mm.
The claws grip behind the panel. The minimum thickness of the panel must be 3
mm and the maximum thickness 20 mm. A panel with less than 5 mm thickness must
be reinforced on the reverse side.
Remove glass from luminaire housing by turning it counter-clockwise.
For connection to external LED-power supply unit – accessory 13 176 or 13 172
– the luminaire is equipped with a 2-pin connector.
Note operating instructions of the LED-power supply units.
Connect plug part of the luminaire with power supply unit.
Push external LED power supply unit and luminaire housing into the ceiling
cut-out.
Tighten guide screws.
When tightening the screws, the fixing claws must swivel onto the inside of
the suspended ceiling. The luminaire is fixed.
When undoing the guide screws, the fixing claws swivel back and the luminaire
can be removed.
Screw the glass into the luminaire housing by turning it clockwise.
Make sure the seal is properly located.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED module · Maintenance
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Clean glass and luminaire regularly with solvent-free cleansers from dirt.
Please follow the installation instructions for the LED module.
Check gasket. Screw in glass by turning it clockwise beyond the stop.
A broken glass must be replaced.
Accessories
Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.
13 176 Power supply unit on/off
13 172 Power supply unit DALI
The power supply units are only suitable for the operation of one LED luminaire.
13 027 Installation housing
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass: 11 003 068 40RG
LED module: 3000 K LED-0445/930
LED module: 4000 K LED-0445/940
Gasket glass: 83 001 459
Customer Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com