BEGA 50636 Recessed Ceiling and Wall Luminaire for Indoor Use
DIMENSION
Application
Recessed ceiling and wall luminaire · indoor luminaire with hand-blown opal
glass, satin matt and metal housing for connection to external LED power
supply unit.
They are ideal for places where a soft and uniform lighting distribution is
required. For installation into ceilings or walls with a shallow depth in
interior areas.
Lamp
Module connected wattage 13.6 W
Luminaire connected wattage 16.3 W
Rated temperature ta=25 °C
Ambient temperature ta max=35 °C
50 636K3
Module designation LED-0328/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 2190 lm
Luminaire luminous flux 1709 lm
Luminaire luminous efficiency 104,8 lm/W
Product description
Luminaire housing made of metal Opal glass, satin matt, with screw neck
Silicone gasket Fixing is achieved by using two adjustable wedge-shaped claws
2 connecting cables with strain relief and plug connector system for BEGA
power supply unit, on/off or DALI
Safety class III
– Conformity mark
Weight: 3.1 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components. You can find them on our website
at www.bega.com.
Installation
Luminaire housing and external LED power supply unit must not be covered by
any heat insulating materials.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
A separate power supply unit is required to operate the luminaire.
For connection to external LED power supply unit – accessory 13 206 or 13 204–
the luminaire is equipped with two 2-pin connectors.
Observe the instructions for use for LED power supply units.
Please note:
The black marked connector is not used to connect to the power supply unit 13
206 on/off.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable
wedge shaped claws.
Installation in solid walls or ceilings
To accommodate the luminaire and the external power supply unit we recommend
using the installation housing – accessory 13 026 -.
Installation in suspended ceilings
A recessed opening of ø 160 mm with a minimum installation depth of 45 mm is
required.
The lateral clearance from the luminaire housing to parts of the building must
be at least 50 mm.
The claws grip behind the panel.
The minimum thickness of the panel must be 3 mm and the maximum thickness 25
mm.
A panel with less than 5 mm thickness must be reinforced on the reverse side.
Open luminaire:
Remove glass from luminaire housing by turning it counter-clockwise.
Connect plug part of the luminaire with power supply unit.
Connect to the LED power supply unit.
Guide the LED power supply unit through the opening in the ceiling and
position it on the suspended ceiling.
Push luminaire housing into the ceiling cut-out.
Tighten evenly screws of claw fasteners.
Screw glass with gasket into luminaire housing.
Make sure that gasket is positioned correctly.
Cleaning – Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets. Defective glass must
be replaced. Close the luminaire
Accessories
Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.
13 206 Power supply unit on/off
13 204 Power supply unit DALI
The power supply units are only suitable or the operation of one LED luminaire.
13 026 Installation housing
For the accessories a separate instructions or use can be provided upon request.
Spares
Spare glass 11 003 470 .0B1RG
LED module 3000 K LED-0328/930