BEGA 50636 Recessed Ceiling and Wall Luminaire for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 50636 Recessed Ceiling and Wall Luminaire for Indoor Use
BEGA 50636 Recessed Ceiling and Wall Luminaire for Indoor
Use

DIMENSION

Application

Recessed ceiling and wall luminaire · indoor luminaire with hand-blown opal glass, satin matt and metal housing for connection to external LED power supply unit.
They are ideal for places where a soft and uniform lighting distribution is required. For installation into ceilings or walls with a shallow depth in interior areas.

Lamp

Module connected wattage 13.6 W
Luminaire connected wattage 16.3 W
Rated temperature ta=25 °C
Ambient temperature ta max=35 °C

50 636K3

Module designation LED-0328/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 2190 lm
Luminaire luminous flux 1709 lm
Luminaire luminous efficiency 104,8 lm/W

Product description

Luminaire housing made of metal Opal glass, satin matt, with screw neck Silicone gasket Fixing is achieved by using two adjustable wedge-shaped claws 2 connecting cables with strain relief and plug connector system for BEGA power supply unit, on/off or DALI
Safety class III
– Conformity mark
Weight: 3.1 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at  www.bega.com.

Installation

Luminaire housing and external LED power supply unit must not be covered by any heat insulating materials.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
A separate power supply unit is required to operate the luminaire.
For connection to external LED power supply unit – accessory 13 206 or 13 204– the luminaire is equipped with two 2-pin connectors.
Observe the instructions for use for LED power supply units.
Please note:
The black marked connector is not used to connect to the power supply unit 13 206 on/off.

The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable wedge shaped claws.
Installation in solid walls or ceilings
To accommodate the luminaire and the external power supply unit we recommend using the installation housing – accessory 13 026 -.

Installation in suspended ceilings

A recessed opening of ø 160 mm with a minimum installation depth of 45 mm is required.
The lateral clearance from the luminaire housing to parts of the building must be at least 50 mm.
The claws grip behind the panel.
The minimum thickness of the panel must be 3 mm and the maximum thickness 25 mm.
A panel with less than 5 mm thickness must be reinforced on the reverse side.
Open luminaire:
Remove glass from luminaire housing by turning it counter-clockwise.
Connect plug part of the luminaire with power supply unit.
Connect to the LED power supply unit.
Guide the LED power supply unit through the opening in the ceiling and position it on the suspended ceiling.
Push luminaire housing into the ceiling cut-out.
Tighten evenly screws of claw fasteners.
Screw glass with gasket into luminaire housing.
Make sure that gasket is positioned correctly.

Cleaning – Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Close the luminaire

Accessories

Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.

13 206 Power supply unit on/off
13 204 Power supply unit DALI

The power supply units are only suitable or the operation of one LED luminaire.

13 026 Installation housing

For the accessories a separate instructions or use can be provided upon request.

Spares

Spare glass 11 003 470 .0B1RG
LED module 3000 K LED-0328/930

CUSTOMER SERVICES

BEGA Gantenbrink-Leuchten KG ·
Postfach 3160 · 58689 Menden ·
info@bega.com ·
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals