  • Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
  • Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage in accordan e with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
  • Lamp Module connected wattage: 8.1 W
  • Luminaire connected wattage: 9.7 W
  • Rated temperature: 25-45°C
  • Ambient temperature: ta = ta max
  • LED-0800/927: Colour temperature – 2700 K, Colour rendering index (CRI) > 90, Module luminous flux – 1200 lm, Luminaire luminous flux – 943 lm, Luminaire luminous efficiency – 97.2 lm/W
  • LED-0800/930: Colour temperature – 3000 K, Colour rendering index (CRI) > 90, Module luminous flux – 1255 lm, Luminaire luminous flux – 986 lm, Luminaire luminous efficiency – 101.6 lm/W

Product Usage Instructions

  1. Installation: LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  2. IMPORTANT: To ensure secure connection, the luminaire housing must be positioned precisely in relation to the mounting plate. Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate. Press the luminaire housing firmly against the mounting plate and turn it clockwise firmly against the stop.
  3. Open luminaire: Unscrew glass from luminaire housing by turning it counter-clockwise. To prevent the luminaire from turning on the mounting plate, hold the luminaire housing in place with one hand.
  4. Replacement of the LED module: The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Defective glass must be replaced. Close the luminaire.

Instructions for use

Application
Ceiling luminaire · Indoor luminaire with wide beam light distribution.

Product Description

  • Aluminium alloy housing, finish Stainless steel
  • Crystal glass, partially satin matt, with screw neck
  • Reflector made of pure anodised aluminium 2 mounting holes ø 4.5 mm
  • Distance apart 96 mm
  • The luminaire is suitable for through-wiring. Connecting terminals 2.5@
  • Earth conductor connection
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 170-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • – Safety mark
  • – Conformity mark
  • Weight: 0.95 kg
  • This product contains light sources of energy efficiency classes EBEGA-50565-2-LED-Ceiling-Luminaire-fig-1

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage: 8.1 W
  • Luminaire connected wattage: 9.7 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 45 °C

50 565.2 K27

  • Module designation: LED-0800/927
  • Colour temperature: 2700 K
  • Colour rendering index: CRI > 90
  • Module luminous flux: 1200 lm
  • Luminaire luminous flux: 943 lm
  • Luminaire luminous efficiency: 97,2 lm / W

50 565.2 K3

  • Module designation: LED-0800/930
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 90
  • Module luminous flux: 1255 lm
  • Luminaire luminous flux: 986 lm
  • Luminaire luminous efficiency: 101,6 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Remove mounting plate from the luminaire housing. Unplug the earth conductor connection (plug contact).

Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire! Lead the power connecting cable through the mounting plate. Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface. Establish the earth conductor connection to the luminaire housing (plug contact). Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection.BEGA-50565-2-LED-Ceiling-Luminaire-fig-4

IMPORTANT:
To ensure secure connection, the luminaire housing must be positioned precisely in relation to the mounting plate. Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate. Press the luminaire housing firmly against the mounting plate and turn it clockwise firmly against the stop.

Open luminaire:
Unscrew glass from luminaire housing by turning it counter-clockwise.
To prevent the luminaire from turning on the mounting plate, hold the luminaire housing in place with one hand.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module. Defective glass must be replaced. Close the luminaire.

Spares

  • Spare glass: 11 003 417 10M RG
  • LED power supply unit: DEV-0141/250
  • LED module 2700 K: LED-0800/927
  • LED module 3000 K: LED-0800/930
  • Reflector: 76 000 980 .2

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals