BEGA 99415 Underwater Floodlight Instruction Manual

June 12, 2024
BEGA

BEGA 99415 Underwater Floodlight

Product Information

The Unterwasserscheinwerfer Underwater floodlight is designed for the illumination of ponds, water pools, and water features up to a depth of 20 meters. It is a water pressure tight floodlight that must only be operated underwater and protected against freezing. The floodlight is made of stainless steel with a clear safety glass and a silicone gasket. It features a reflector made of pure anodized aluminum. The LED power supply unit operates at 220-240 V and 50-60 Hz. The luminaire has a safety class I and protection class IP68, making it suitable for underwater use up to a depth of 20 meters. The weight of the floodlight is 4.2 kg.

Product Usage Instructions

  • To avoid damages on the surface of the floodlight, ensure that the water has a neutral pH-value and is free from metal attacking ingredients.
  • Before installing the floodlight, consult national safety regulations and ensure that the installation and operation are carried out by a qualified electrician.When designing a lighting installation underwater, consider that the amount of light absorbed by the water depends on its clarity. The lighting intensity and brightness will be lower compared to a free burning floodlight.
  • The values shown in the floodlight diagram are valid for medium air. In clear water at a distance of 10 meters, the lighting intensity is approximately half that of a free burning floodlight.
  • Do not modify the luminaire without proper authorization. Any modifications should be carried out by the manufacturer or authorized personnel.

DIMENSIONS

BEGA-99415-Underwater-Floodlight-FIG-1

Instructions for use

Application

  • Water pressure tight underwater floodlight for the illumination of ponds, water pools and water features up to a depth of 20 metres.
  • The floodlight must only be operated under water and must be protected against freezing in.
  • To avoid damages on the surface of the floodlight, the water must have a neutral pH-value and should be free from metal attacking ingredients.

Lamp

  • Module connected wattage 15.5 W
  • Luminaire connected wattage 20.8 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C

99 415 K3

  • Module designation LED-1165/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 3010 lm
  • Luminaire luminous flux * 2169 lm
  • Luminaire luminous efficiency 104,3 lm / W preliminary data

Product Description

  • Luminaire-made stainless steel
  • Steel grade no. 1.4301 – electropolished
  • Clear safety glass
  • Silicone gasket
  • Reflector made of pure anodised aluminium Swivel range 90°
  • Mounting bracket with 2 holes ø 7 mm · 45 mm spacing water-resistant connecting cable
  • H07RN8-F 3 G 1@
  • Cable length 4 m
  • LED power supply unit 220-240 V 50-60 Hz
  • Safety class I
  • Protection class IP 68 20 m
  • Dust-tight and water pressure tight
  • Maximum submersion depth 20 m
  •  – Conformity mark
  • Weight: 4.2 kg
  • This product contains light sources of energy efficiency class(es) C

Light technique

  • Floodlight with narrow beam light distribution.
  • Half beam angle 16°
  • When designing a lighting installation under water, note that the amount of light absorbed by the water depends on the clarity of the water.
  • Lighting intensity and brightness are less than with a free burning floodlight.
  • The values shown in the floodlight diagram are only valid for medium air.
  • In clear water at a distance of 10 m, the lighting intensity is about half that of a free burning floodlight.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at  www.bega.com.

Installation

  • The floodlight can only be used under water.
  • The electrical connection at the luminaire connecting cable must be carried out on site according to the protection class and safety class.
  • Switch on the lamp for only short time when out of water.
  • Undo hexagon nuts and remove floodlight housing from the slotted fixing bracket.
  • Fix the mounting bracket on the mounting surface using delivered stainless steel screws.
  • Insert the floodlight housing into the slotted fixing bracket, align and fix it.
  • Tighten hexagon nuts firmly and evenly. Torque = 5 Nm.

Cleaning · Maintenance

  • Soilings and foulings on the stainless steel parts should be removed frequently. They can be removed with suitable stainless steel cleansers.
  • For cleaning do not use high pressure cleaners.

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacement of the LED module · Maintenance

  • Disconnect the electrical installation.
  • LED are high-quality electronic components ! Please avoid touching the light output opening of the LED directly during relamping.
  • Undo hexagon nuts and remove floodlight housing from the slotted fixing bracket.
  • Lift floodflight above water level and relamp.
  • Open the floodlight: Undo counter sunk screws.
  • Lift cover ring and glass with gasket.
  • Remove reflector.
  • Undo hexagon socket head screws M4 and remove LED-unit.
  • Replace LED-Module.
  • Note installation instructions of the LED module. Clean the luminaire (see Cleaning · Maintenance).
  • Check the gaskets and replace, if necessary.
  • The luminaire housing must be completely clean and absolutely dry.
  • Insert LED-unit and fix it.
  • Insert reflector.
  • Place the glass between the gaskets and into the housing.
  • Make sure that gasket is positioned correctly.
  • Apply cover ring and firmly tighten countersunk-head screw crosswise.
  • Torque = 3.5 Nm.
  • Test the lamp outside the water only for a short time.
  • Insert the floodlight housing into the fixing bracket, align and fix it.
  • Tighten hexagon nuts firmly and evenly.
  • Torque = 5 Nm.
  • Only correctly positioned gaskets and tight screw cable glands guarantee a watertight housing.

Spares

  • Spare glass 14 000 036
  • LED power supply unit DEV-0179/24V
  • LED module 3000 K LED-1195/830
  • Reflector 76 001 463
  • Gasket glass 82 000 170
  • Gasket insert 83 001 756

BEGA Gantenbrink-Leuchten KG