Instructions for use
Application
Recessed ceiling and wall luminaire · indoor luminaire with hand-blown opal
glass, satin matt and aluminium housing and with external LED power supply
unit. Luminaire with adjustable colour temperature (Tunable White). They are
ideal for places where a soft and uniform lighting distribution is required.
For installation into ceilings with a shallow depth in interior areas.
Product description
- Recessed LED-ceiling and wall luminaire with a remote DALI controllable power supply unit Luminaire housing made of aluminium
- Opal glass, satin matt, with screw neck Silicone gasket
- Recessed opening ø 166 mm
- Required installation depth 65 mm
- Luminaire housing with 3 fixing claws and guide screws
- 2-pole connecting terminal for digital control
- BEGA Ultimate Driver®
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-264 V
- During DC operation the LED power
- is reduced to 50 %
- DALI controllable (Device Type 8 for Tunable White according to IEC 62386-209)
- A basic isolation exists between power cable and control line
- Safety class II 2
- – Safety mark
- – Conformity mark
- This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp
- Module connected wattage: 8.5 W
- Luminaire connected wattage: 9.8 W
- Rated temperature: ta = 25 °C
- Ambient temperature: ta max = 55 °C
- When installed in heat-insulating material: ta max = 50 °C
- Module designation: LED-0802/9TW
- Colour temperature: adjust. 2700 – 6500 K
- Colour rendering index: Ra > 90
- Module luminous flux: 1000 lm
- Luminaire luminous flux : 620 lm
- Luminaire luminous efficiency: 63,3 lm / W
preliminary data
Setting the colour temperature
The LED colour temperature of the luminaire can be set from 2700 to 6500 K
(“Tunable White”). Please note: To be able to set the LED colour temperature,
the controller used must support DALI Device Type 8. If no LED colour
temperature setting is made, 3000 K will be used by default.
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. The recessed opening is covered by the frame of the luminaire housing. Fixing of the luminaire in the structure is achieved by using three adjustable wedge- shaped claws.
Installation in solid walls or ceilings
To accommodate the luminaire and the external power supply unit we recommend
using the installation housing 13 027.
Please note:
To ensure that the luminaire is securely held in the plastered installation
housing, it is essential to unscrew the screws on the underside of the
fastening claws and remove the adapter for the fastening claws (see drawing).
Installation in suspended ceilings
A recessed opening of ø 166 mm with a minimum installation depth of 65 mm is
required.The lateral distance between the luminaire housing and parts of the
building must be at least 50 mm. The claws grip behind the panel. The minimum
thickness of the panel must be 3 mm and the maximum thickness 20 mm. A panel
with less than 5 mm thickness must be reinforced on the reverse side. Remove
glass from luminaire housing by turning it counter-clockwise. Open cover of
the LED-power supply unit and lead mains supply cable into it. Make electrical
connection to the terminals. For digital control please use the connecting
terminal DA, DA. In case this terminal is not used the luminaire will be
operated at full light output. Close cover of the LED-power supply unit. Push
external LED power supply unit and luminaire housing into the ceiling cut-out.
Tighten guide screws. When tightening the screws, the fixing claws must swivel
onto the inside of the suspended ceiling. The luminaire is fixed. When undoing
the guide screws, the fixing claws swivel back and the luminaire can be
removed. Screw the glass into the luminaire housing by turning it clockwise.
Make sure the seal is properly located.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Inspect and,
if necessary, replace the luminaire gaskets. Defective glass must be replaced.
Close the luminaire.
Accessories
13 027 Installation housing
For the accessories a separate instructions for use can be provided upon
request.
Spares
- Spare glass: 11 003 063 40R G
- LED power supply unit: DEV-0264/250
- LED module: LED-0802/9TW
- Gasket glass: 83 001 459