Product Information
- Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should be done by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation.
- Overvoltage Protection: The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.
- Lamp Module Connected Wattage: 34.8 W
- Luminaire Connected Wattage: 39 W
- Rated Temperature: 25°C
- Ambient Temperature: 35°C
- Module Designation: 50 070.2 K3
- Colour Temperature: 3000 K
- Colour Rendering Index (CRI): > 90
- Module Luminous Flux: 5790 lm
- Luminaire Luminous Flux: 4262 lm
- Luminaire Luminous Efficiency: 109.3 lm / W
Product Usage Instructions:
- To replace the LED module, refer to the label inside the luminaire for the module designation.
- Disconnect the system and open the luminaire.
- Follow the installation instructions for the LED module. Use standard tools for replacement.
- If the glass is defective, replace it.
- Close the luminaire after replacing the module and/or glass.
Instructions for use
Application
Free radiating wall luminaire · indoor luminaire with hand-blown three-ply
opal glass for a soft and uniform light distribution.
The elongated design of this wall luminaire particulary provides suitability
for installation on pillars, columns and for the front surface of walls, as
well as for recesses or profiles.
The luminaire may be installed horizontally or vertically.
Product description
- Metal luminaire housing, finish Stainless steel
- Hand-blown opal glass
- The electrical equipment can be hinged
- 2 mounting holes ø 6 mm
- Distance apart 640 mm
- Jointing sleeve with
- cable entry for mains supply cable up to
- ø 14 mm, max. 5 x 1.5@
- Connecting terminals 2.5@
- Earth conductor terminal
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-276 V
- During DC operation the LED power is reduced to 15 %
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK02
- Protection against mechanical
- impacts < 0.2 joule
- – Safety mark
- – Conformity mark
- Weight: 4.4 kg
- This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp
- Module connected wattage: 34.8 W
- Luminaire connected wattage: 39 W
- Rated temperature: ta = 25 °C
- Ambient temperature: ta max = 35 °C
50 070.2 K3
- Module designation: 6x LED-0627/930
- Colour temperature: 3000 K
- Colour rendering index: CRI > 90
- Module luminous flux: 5790 lm
- Luminaire luminous flux: 4262 lm
- Luminaire luminous efficiency: 109,3 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Undo hexagon socket (wrench size 5) in the locking cap and remove it. The opal glass can now be hinged together with the electrical equipment to the front. Remove opal glass. Note position of application of the luminaire arrow down«. Drill mounting holes into the mounting surface-spacing 640 mm and turn in enclosed or suitable fixing screws. For the electrical connection undo the screw connection at the line connector and remove terminal block. Make earth conductor connection and electrical connection. Make connection of the phase with the L marked, the neutral wire at the N marked and earth conductor at the PE marked connecting terminal. For digital actuation please use the two connecting terminals DA. If these terminals are not assigned, the luminaire will work with full light output. Bolt together both screw cable glands firmly. Hook luminaire into the fixing screws and tighten. Slide opal glass over the lamp and fasten with the locking cap. Make sure that the gaskets are positioned correctly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools.Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Defective
glass must be replaced. Close the luminaire.
Spares
- Spare glass: 11 003 176 .1R G
- LED power supply unit: DEV-0159/700i
- LED module 3000 K: LED-0627/930
- Gasket glass 2x: 83 000 788
BEGA Gantenbrink-Leuchten KG