BEGA 50576.6 LED Recessed Ceiling Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 50576.6 LED Recessed Ceiling Luminaire

BEGA-50576.6 LED-Recessed-Ceiling-Luminaire-product

Product Usage Instructions

Safety:
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should only be carried out by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection:
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients, it is recommended to use separate overvoltage protection components. These components can be found on our website at www.bega.com.

Facility:
The luminaire housing and external LED power supply unit should not be covered by any heat-insulating materials. During installation or relamping, avoid touching the light output opening of the LED directly as they are high- quality electronic components.

Replacing the LED Module:
The designation of the LED module is noted on a label in the luminaire. When replacing the module, ensure that the light color and light output of the replacement module correspond to those of the original module. The module can be replaced by qualified persons using standard tools. To replace the module, disconnect the system, open the luminaire, follow the installation instructions for the LED module, and then close the luminaire.

Spares:
For spares, the following components are available: LED power supply unit (DEV-0375/350) and LED module 3000 K (LED-0859/930).

Application

  • Recessed ceiling luminaire · indoor luminaire with symmetrical wide beam light distribution and a remote non-dimmable power supply unit.
  • For installation in suspended ceilings of 5-30 mm in interior applications.

Lamp Specification

  • Module connected wattage 10 W
  • Luminaire connected wattage 11.8 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

50 576.6 K3

  • Module designation LED-0859/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1355 lm
  • Luminaire luminous flux 537 lm
  • Luminaire luminous efficiency 45,5 lm / W

Product Description

  • Recessed LED ceiling luminaire with a remote power supply unit
  • Luminaire housing made of cast aluminum
  • Ceiling trim ring finish, Colour velvet black
  • Inside hue matt copper
  • Fixing is achieved by using 2 fastening springs
  • Recessed opening ø 120 mm
  • Required installation depth of 80 mm
  • Light-diffusing disc
  • External LED power supply unit 220-240 V x 0/50-60 Hz
  • Safety Class II 2
    • Safety mark
    • Conformity mark
  • Weight: 0.41 kg
  • This product contains light sources of energy efficiency class(es) E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Installation

Luminaire housing and external LED power supply unit must not be covered by any heat-insulating materials.

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.

  • Cover the recessed opening with the stop ring of the luminaire housing.
  • The luminaire housing is then fixed in the recessed opening via two springs.

Installation in suspended ceilings:

  • A recessed opening of 120 mm with a minimum depth of 80 mm is required.
  • The minimal thickness of the ceiling panel must be 5 mm and must not be greater than 25 mm.
  • A ceiling panel with less than 5 mm thickness must be reinforced on the reverse.
  • The electrical connection must be made on-site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
  • Ensure the correct assignment of the connecting cable. Establish the main connection on the brown (L) and blue (N) wires.
  • Guide the LED power supply unit through the opening in the ceiling and position it on the suspended ceiling.
  • Compress the fastening springs of the luminaire housing on both sides and slide the luminaire housing into the recessed opening.
  • The fastening springs lock into place behind the ceiling panel.

Dimension

BEGA-50576.6 LED-Recessed-Ceiling-Luminaire-fig-1

Cleaning And Maintenance

Clean the luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0375/350
  • LED module 3000 K LED-0859/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals