Product Information

  • Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should only be done by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation.
  • Overvoltage Protection: The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. Additional protection against transients is recommended through separate overvoltage protection components, available on the manufacturer’s website.
  • Lamp Module Connected Wattage: 4.8 W
  • Luminaire Connected Wattage: 6.2 W
  • Rated Temperature: 25°C – 55°C
  • Ambient Temperature: max 55°C
  • Module Designation: LED-0345/930
  • Colour Temperature: 3000 K
  • Colour Rendering Index (CRI): >90
  • Module Luminous Flux: 775 lm
  • Luminaire Luminous Flux: 461 lm
  • Luminaire Luminous Efficiency: 74.4 lm/W

Product Usage Instructions

  1. If the luminaire is to be mounted onto a metallic, electroconductive surface, ensure that the mounting surface is connected conductive to the earth conductor of the luminaire.
  2. During installation or relamping, avoid touching the light output opening of the LED directly.
  3. To open the luminaire:
    • Loosen the lateral knob and remove the cap.
    • Take out the glass component and loosen the isolating plug (LED-lines).
  4. Pull silicone sleeves over the wires, make an earth connection, and electrical connection to the terminal.
  5. Mount the luminaire housing with suitable fixing material onto the mounting surface.
  6. Take the glass component and reconnect the isolating plug (LED-lines). Ensure to lead the lines back through the cable routing to avoid damaging them.
  7. Place the glass into the luminaire housing, close the luminaire with the cap, and screw in the knob into the cap.

Dimension

BEGA-23-080.1-Wall-Luminaire-for-Indoor-Use-FIG-1

Instructions for use

Application
Wall luminaire · indoor luminaire made of handblown opal glass, with metal housing. The light aperture can be adjusted infinitely by rotating the the shield around its longitudinal axis. Light aperture 170°; adjustable 300°.

Product description
Die-cast aluminium and aluminium housing, finish Colour white Hand-blown opal glass 2 elongated fixing holes Width 4.5 mm · 220,5 mm spacing Built-in toggle switch Connection terminal 2.5@ Earth conductor connection LED power supply unit 220-240 V x 0/50-60 Hz  DC 170-280 V Safety class I r – Safety mark c – Conformity mark Weight: 0.8 kg This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

  • Lamp
    • Module connected wattage 4.8 W
    • Luminaire connected wattage 6.2 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 55 °C
  • 23 080.1 K3
    • Module designation LED-0345/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 775 lm
    • Luminaire luminous flux 461 lm
    • Luminaire luminous efficiency 74,4 lm / W

Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductively to the earth conductor of the luminaire!
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. To open the luminaire: Loosen lateral knob and remove cap. Take out glass component and loosen the isolating plug (LED-lines). Pull silicone sleeves over the wires, make earth connection and electrical connection to the terminal. Mount luminaire housing with suitable fixing material onto the mounting surface. Take the glass component and reconnect the isolating plug (LED-lines). It is imperative to lead the lines back through the cable routeing to avoid damaging of lines by the rotating mechanism. Place glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Relamping · Maintenance

Disconnect from main supply. Loosen lateral knob and remove cap. Take out glass component and loosen the isolating plug (LED-lines). Remove the teflon ring at the opening side of the light shade. Clean glass and luminaire regularly with solvent-free cleansers from dirt. Disassemble LED module. Assemble LED replacement module. Insert glass component into the light shade and remount the teflon ring. Take the glass component and reconnect the isolating plug (LED-lines). It is imperative to lead the lines through the cable routeing to avoid damaging of lines by  the rotating mechanism.Place glass into luminaire housing, close luminaire with the cap and screw in the knob into the cap. A broken glass must be replaced.

  • Spares
    • Spare glass 11 002 931 .1R G
    • LED power supply unit DEV-0189/350
    • Switch 63 000 360
    • LED module 3000 K LED-0345/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com