BEGA 50 094.1 Wall Luminaire for Indoor Use Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 50 094.1 Wall Luminaire for Indoor Use
DIMENSION
Instructions for use
Application
Enclosed and free-radiating wall luminaire made of hand-blown opal glass, with
metal housing, for all lighting tasks in interior applications.
Product Description
Metal luminaire housing, finish Colour white Hand-blown opal glass Metal
shield, white 2 mounting holes ø 4.5 mm Distance apart 250 mm 2 cable entries
for through-wiring for connection cable up to ø 10,5 mm max. 5 x 1.5@
Connection terminal 2.5@ Earth conductor connection 2-pole connecting terminal
for digital control BEGA Ultimate Driver® LED power supply unit 220-240 V x
0/50-60 Hz DC 176-276 V DALI-controllable Basic insulation is provided between
the mains and control cables BEGA Thermal Control® Temporary thermal
regulation to protect temperature-sensitive components without switching off
the luminaire Safety class Ir – Safety mark c – Conformity mark Weight: 1.1
kg This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DINÂ ENÂ 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 16.4 W
- Luminaire connected wattage 19 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
50 094.1 K3
- Module designation LED-0594/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 2415 lm
- Luminaire luminous flux 1360 lm
- Luminaire luminous efficiency 71,6 lm / W
Installation
The luminaire must only be operated with the complete protective cover. LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Lead the mains supply cable through the cable entry into the luminaire housing. Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface. Be sure to use the gasket rings supplied. Establish earth conductor connection and make the electrical connection to the terminals. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. Insert the glass into the luminaire housing and fix it by screwing the shield hand-tight clockwise onto the glass.
Cleaning · Maintenance
Clean the luminaire regularly with solvent-free cleansers from dirt. The defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The
light color and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. The defective
glass must be replaced. Close the luminaire.
Spares
- Spare glass 11 003 168 .0
- LED power supply unit DEV-0312/700
- LED module 3000 K LED-0594/930
- Shield 72 000 896 M
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com