BEGA 50132 LED Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA-logo

BEGA 50132 LED Wall Luminaire

Product Information

  • Product Description: Glashaltestangen Edelstahl
  • Material: Mundgeblasenes Opalglas
  • Spacing: 130 x 195 mm
  • Earth Conductor Connection: Yes
  • Dimming Compatibility: Phase angle or phase section dimming,
  • 220-230 V, 50/60 Hz
  • Weight: 1.2 kg
  • Energy Efficiency Class: F
  • Overvoltage Protection: Yes
  • Lamp Connected Wattage: 14 W
  • Colour Temperature: 3000 K
  • Colour Rendering Index: Ra > 90
  • Module Luminous Flux: 1320 lm
  • Luminaire Luminous Flux: 1158 lm
  • Luminaire Luminous Efficiency: 82.7 lm/W

Product Usage Instructions

  1. The installation and operation of this luminaire should comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning.
  2. Ensure that the product is mounted and connected according to the instructions provided in the user manual to prevent any damage or malfunction.
  3. For additional protection against overvoltage and transients, it is recommended to use separate overvoltage protection components. Visit our website at www.bega.com for more information.
  4. To clean the product, use suitable cleansers and avoid using abrasive materials that could damage the surface.
  5. In case of defective glass, it should be replaced with a new one to maintain the product’s functionality and safety.
  6. If needed, the LED module can be replaced with the LED module 3000 K. Refer to the spare part numbers for ordering: 11 003 199 .1R G 51 002 942.

Dimension

BEGA-50132-LED-Wall-Luminaire-FEATURED

Instructions for use

Application
Open and free-radiating wall luminaire · indoor luminaire with hand-blown opal glass and metal bracket.The character of the opal glass creates a smooth and uniform light distribution in the room
Product description
Aluminium fitter, finish Colour white Stainless steel glass holding bolts Hand-blown opal glass 3 fixing holes ø 6.5 mm 130 x 195 mm spacing 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@ Connection terminal 2.5@ Earth conductor connection LED module for power supply Suitable for phase angle or phase section dimming 220-230 V y 50/60 Hz BEGA Thermal Switch® Temporary thermal shutdown to protect temperature- sensitive components Safety class I r – Safety mark c – Conformity mark Weight: 1.2 kg This product contains light sources of energy efficiency class(es) F

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.The manufacturer accepts no liability for  damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

  • Lamp
    • Luminaire connected wattage 14 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 25 °C
  • 50 132 K3
    • Module designation LED-1246/930
    • Colour temperature 3000 K
    • Colour rendering index Ra > 90
    • Module luminous flux 1320 lm
    • Luminaire luminous flux 1158 lm
    • Luminaire luminous efficiency 82,7 lm / W

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Lead the mains supply cable through the cable entry of the luminaire base. Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Notice position of use “arrow down” of the luminaire base. Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection. Mount glass to luminaire base with the glass holding bolts.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified electrician or a comparably qualified person using standard tools. Disconnect the system. Remove glass by unscrewing glass holding bolts. Please follow the installation instructions for the LED module. Defective glass must be replaced. Mount glass to luminaire base with the glass holding bolts.

  • Spares
    • Spare glass 11 003 199 .1R G
    • Glass holding bolt 51 002 942
    • LED module 3000 K LED-1246/930

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com