BEGA 24 714 Ceiling and Wall Luminaire
DIMENSION\
Application
- Unshielded ceiling and wall luminaire with high protection class.
- A luminaire made of aluminium alloy and crystal glass.
Product description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Crystal glass, white inside 2 mounting holes ø 4.5 mm
- Distance apart 325 mm 2 screw cable glands with strain relief for through-wiring power connecting cable ø 7–12 mm 1 screw cable gland closed at the factory with a dummy plug
- Connection terminal 2.5@
- Earth conductor connection
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-280 V
- DC Start ≥ 190 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I p Ballproof – The testing of ball impact safety was carried out exclusively with handballs in accordance with DIN 18032-3: 2018-11. Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK10
- Protection against mechanical impacts < 20 joule
- Safety mark
- CE- Conformity mark
- Weight: 4.0 kg
- This product contains light sources of energy efficiency class(es) C, D
Safety
- The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to
the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Lamp
- Module connected wattage 23.9 W
- Luminaire connected wattage 27.8 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 40 °C
24 714 K3
- Module designation LED-0993/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 3975 lm
- Luminaire luminous flux 2651 lm
- Luminaire luminous efficiency 95,4 lm / W
24 714 K4
- Module designation LED-0993/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 4180 lm
- Luminaire luminous flux 2788 lm
- Luminaire luminous efficiency 100,3 lm / W
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Installation
- Undo hexagon socket head screws (wrench size 3 mm) through the opening in the luminaire housing up to the stop and lift luminaire top.
- Disconnect the earth conductor connection from the plug connection.
- Disconnect plug-connection of the LED connecting cable.
- Lead the mains supply cable through the screw cable gland into the luminaire back housing. The installed black gasket insert is intended for cables ø < 10 mm.
- For cables ø 10-12 mm the enclosed grey gasket insert must be used.
- In case of through-wiring replace the factory installed dummy plug with the enclosed corresponding gasket insert.
- At the same time, use the enclosed synthetic cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm) (see sketch).
- In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
- Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
- Connect the green and yellow protective earth conductor from the luminaire top to the terminal marked 1 in the luminaire base.
- Connect the LED connection cable by means of a plug connector.
- Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
- Tighten screw cable glands firmly.
- Make the earth conductor connection and the electrical connection.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Connect the green and yellow protective earth conductor from the luminaire top to the terminal marked 1 in the luminaire base. Connect the LED connection cable by means of a plug connector.
Make sure that gasket is positioned correctly. Tighten grub screws evenly.
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high pressure cleaners.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Close the luminaire.
Spares
- Spare glass 11 003 519
- LED power supply unit DEV-0343/700
- LED module 3000 K LED-0993/830
- LED module 4000 K LED-0993/840
- Gasket glass 83 001 927
- Gasket housing 83 002 166 B1
ADDRESS: BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden ·
info@bega.com ·
www.bega.com