BEGA 51 074.1 Recessed Ceiling Luminaire for Indoor Use Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
- BEGA 51 074.1 Recessed Ceiling Luminaire for Indoor Use
- Product Information
- Product Usage Instructions
- Application
- Product Description
- Safety
- Overvoltage protection
- Lamp Specification
- Lighting technology
- Installation
- Dimension
- Cleaning And Maintenance
- Replacing the LED module
- Spares
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BEGA 51 074.1 Recessed Ceiling Luminaire for Indoor Use
Product Information
Safety:
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning must be carried out by a
qualified electrician. The manufacturer is not liable for damage caused by
improper use or installation. Any modifications made to the luminaire should
be done by a responsible person who will be considered the manufacturer.
- Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on our website at www.bega.com.
- Lamp: The connected wattage of the module is 7.8 W and the connected wattage of the luminaire is 9.2 W.
- Temperature: The rated temperature is 25°C to 35°C.
- Module Information: The module designation is LED-1021/930 with a color temperature of 3000 K. The color rendering index (CRI) is greater than 90. The module luminous flux is 1180 lm and the luminaire luminous flux is 660 lm. The luminaire luminous efficiency is 71.7 lm/W.
Product Usage Instructions
Installation:
The luminaire housing and external LED power supply unit should not be covered
by any heat-insulating materials. Avoid touching the light output opening of
the LED directly during installation or relamping, as the LED components are
sensitive.
Replacing the LED Module:
- Identify the LED module designation noted on a label in the luminaire.
- Ensure that the light color and light output of the replacement module match the original module.
- Disconnect the system and open the luminaire.
- Follow the installation instructions for the LED module provided by the manufacturer.
- Close the luminaire after replacing the module.
Spares:
- LED Power Supply Unit: LED-1021/930 76 001 891 B1
- LED Module 3000 K: DEV-0385/350i
- Reflector: LED-1021/930 76 001 891 B1
Application
- Recessed ceiling luminaire · indoor luminaire with symmetrical broad spread light distribution and a remote controllable power supply unit.
- For surface-mounted installation in indoor suspended ceilings of 5-30 mm thickness.
Product Description
- Recessed ceiling luminaire »STUDIO LINE« with a remote power supply unit
- Luminaire housing made of cast aluminium
- Ceiling trim ring finish, Colour velvet black
- Inside hue white enamel
- Fixing is achieved by using 2 fastening springs
- Recessed opening ø 100 mm
- Required installation depth 75 mm
- Light-diffusing disc
- External LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-275 V
- DALI controllable
- A basic isolation exists between power cable and control line
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class II
- Conformity mark
- Weight: 0.38 kg
- This product contains light sources of energy efficiency class(es) D
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp Specification
- Module connected wattage 7.8 W
- Luminaire connected wattage 9.2 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 35 °C
51 074.1 K3
- Module designation LED-1021/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1180 lm
- Luminaire luminous flux 660 lm
- Luminaire luminous efficiency 71,7 lm / W
Lighting technology
Symmetrical wide beam light distribution Half beam angle 60°
Installation
Luminaire housing and external LED power supply unit must not be covered by any heat insulating materials.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
- Cover the recessed opening with the stop ring of the luminaire housing.
- The luminaire housing is then fixed in the recessed opening via two springs.
Installation in suspended ceilings:
- A recessed opening of 100 mm with a minimum depth of 75 mm is required.
- The minimal thickness of the ceiling panel must be 5 mm and must not be greater than 30 mm.
- A ceiling panel with less than 5 mm thickness must be reinforced on the reverse.
- The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
- Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires.
- The connection of the control cables is achieved by means of the both leads marked with – DALI.
- In case these leads are not used the luminaire will be operated at full light output.
- Guide the LED power supply unit through the opening in the ceiling and position it on the suspended ceiling.
- Compress the fastening springs of the luminaire housing on both sides and slide the luminaire housing into the recessed opening.
- The fastening springs lock into place behind the ceiling panel.
Dimension
Cleaning And Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Close the luminaire.
Spares
- LED power supply unit DEV-0385/350i
- LED module 3000 K LED-1021/930
- Reflector 76 001 891 B1
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>