camry CR 7970 Ultrasonic Aroma Diffuser User Manual

June 12, 2024
camry

camry CR 7970 Ultrasonic Aroma Diffuser User Manual
Ultrasonic Aroma Diffuser

GENERAL SAFETY TERMS

MPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND KEEP FOR FUTURE REFERENCE

Warranty conditions are different if the device is used for commercial purposes.

  1. Before using the device, read the user manual and follow the instructions contained therein. The manufacturer is not liable for damage caused by using the device contrary to its intended use or improper operation.
  2. The device is for home use only. Do not use it for other purposes that are inconsistent with its intended use.
  3. The device should only be connected to a 220-240 V ~ 50 Hz power socket. In order to increase the safety of use, many electrical devices should not be connected to one power circuit at the same time.
  4. Be especially careful when using the device when children are around. Do not allow children to play with the device and do not allow children or people unfamiliar with the device to use it.
  5. WARNING: This equipment can be used by children over 8 years of age and persons with reduced physical, sensory or mental abilities, or persons without experience or knowledge of the equipment, if it is carried out under the supervision of a person responsible for their safety or they have been given instructions on the safe use of the device and are aware of the dangers associated with its use. Children should not play with the equipment. Cleaning and user maintenance should not be performed by children, unless they are over 8 years of age and are supervised.
  6. Always remove the plug from the power socket after use by holding the power socket with your hand. DO NOT pull on the net cord.
  7. Do not immerse the cord, plug or the entire appliance in water or any other liquid. Do not expose the device to weather conditions (rain, sun, etc.) or use it in high humidity conditions (bathrooms, damp mobile homes).
  8. Periodically check the condition of the power cord. If the power cord is damaged, it should be replaced by a specialist repair facility in order to avoid a hazard.
  9. Do not use the appliance with a damaged power cord or if it has been dropped or damaged in any other way or is not working properly. Do not repair the device yourself, as it may cause electric shock. Return the damaged device to the appropriate service centerfor inspection or repair. Any repairs may only be made by authorized service points. Improperly performed repair may result in serious danger to the user.
  10. Place the appliance on a cool, stable, level surface, away from heating appliances such as electric cookers, gas burners, etc.
  11. Do not use the device near flammable materials.
  12. The power cord must not hang over the edge of the table or touch hot surfaces.
  13. Do not leave the device switched on or the mains adapter unattended.
  14. For additional protection, it is advisable to install a residual current device (RCD) in the electrical circuit with a rated residual current not exceeding 30 mA. Please consult an electrician for this.
  15. It is forbidden to insert fingers or any other objects into openings in the device casing.
  16. Do not cover the discharge opening.
  17. After finishing work, empty the device of water before storing it away.
  18. If the device will not be used for a long time, disconnect it from the mains.
  19. Do not move the machine when there is water in the internal tank.
  20. Do not place any objects on the device.
  21. The device should only be used with recommended fragrances. The use of other substances may result in a toxic or fire hazard.
  22. The device may only be used with efficient ventilation.
  23. An unusual smell, noise, or abnormal heating indicates a product or power adapter failure, immediately remove the power adapter from the wall outlet and stop using the device.
  24. Please do not put the adapter in water or use it when it is wet. Do not store the power supply in a damp place.

BEFORE FIRST USE

  1. Keep in mind that high humidity levels can encourage the growth of biological organisms in the environment.
  2. Do not allow the area around the device to become damp or wet. If moisture occurs, lower (reduce) the mist output. Do not allow absorbent materials such as carpets, curtains, tablecloths to get wet.
  3. Place this device on a flat surface. Do not place this product on a carpet, rug or other uneven place.
  4. Do not place this device near electrical appliances such as TV or sound equipment, etc. Do not let it splash directly on furniture, clothes or walls, etc.

PRINCIPLE OF OPERATION
Through the ultrasonic wave, the diffuser breaks the water and essential oil into tiny particles a cold mist diffuses a fresh aroma.

WHICH OIL TO CHOOSE?
This aroma diffuser requires the use of water. There are no restrictions on what kind of oil is added to the water, both essential oil/aroma oil/complex oils / fragrance water are suitable for use.

PRODUCT DESCRIPTION: Aroma Diffuser CR 7970

Product Instruction

  • A. Spray nozzle
  • B. Top cover
  • C. Inner cover
  • D. Air outlet
  • E. Water tank
  • F. Housing
  • G1. Spray button “MIST
  • G2. Blacklight button “LIGHT”
  • H. Air inlet
  • I. DC connector
  • J. Drain hole
  • K. Chip spraying ultrasonic waves

USE
Place the device in the place of intended use and do not move it during use.

  1. Hold the product upright and remove the top cover (B) vertically. (Fig.1)

  2. Connect the DC plug of the power adapter to the DC connector of the device (I). **(Fig.2)

**

  1. Add water to the water tank (E) using a measuring cup / glass and do not exceed the maximum water level equal to a volume of 100 ml. Only tap water or purified water is suitable for this product. Do not add water during use when the device is running. (Fig.3) Only add cold or lukewarm water. Pour the aroma oil into the water tank. The recommended dose is 0.10 0.15 ml per 100 ml of water. Essential oil can cause discoloration. If it accidentally spills, wipe it off quickly with a cloth.

NOTE: Do not block the spray nozzle to avoid damaging the product.

  1. Replace the top cover (B) vertically to keep the diffuser tight. (Fig.4)

    Note: The top cover (B) should be closed before use.

  2. Connect the plug of the AC adapter to the power socket, the device is now in standby mode. SPRAY ADJUSTMENT: button G1.

    • Press the spray button (right button) “MIST” once: the device sprays the mist continuously until the device switches off automatically due to the consumption of water previously poured in.

    • Press the spray button (right button) “MIST” again: the device will switch to intermittent mode. Itwill alternately generate mist for 30 seconds and stop producing mist for another 30 seconds. The cycles will repeat until the water in the tank runs out, then the device will turn off automatically.

    • Press the spray button (right button) “MIST” a third time: the device stops generating mist. (Fig.5) LIGHT ADJUSTMENT: button G2.

    • Press the backlight button (left button) “LIGHT” once: you will turn on the warm light in bright mode,

    • Press the backlight button (left button) “LIGHT” again: you will turn on the warm light in dimmer mode.

    • Press the backlight button (left button) “LIGHT” a third time: the light will be turned off. (Fig.6)

  3. If there is no water in the water tank (E), the diffuser will be turned off automatically even when you press the spray button.

  4. The product cannot be used if there is no water in the water tank (E).
    NOTE: The mist concentration may vary slightly, which is normal. Different types of water, humidity, temperature and air velocity affect spray intensity.

  5. Before replacing with another oil, please clean the device according to the maintenance instructions.

  6. Never leave water in the tank (E), when the device is not in use.

  7. After working for a long time, turn it off for 60 minutes to avoid damaging the ultrasonic wave chip restart it.

ACCIDENTAL LEAK
If you accidentally knock over this device during use, follow these steps:

  1. Turn off the power. Detach the device and open the top cover (B) to pour out all the remaining water from the water tank (E).
  2. Gently shake the device to drain the internal water through the drainage hole (J) in the base.
  3. Air dry the device in a safe place for 24 hours.

DESCALING
If the aroma diffuser has scale sediment caused by water, can add white vinegar to the water to dissolve the scale and then rinse with water. Then, use soft cloth to wipe the water. Never use strong cleansing agent.

TROUBLESHOOTING

If this product is not working normally, please follow these steps for self- troubleshooting before sending the return to the seller:
PROBLEM 1: The product automatically turns off in one second when the spray button “MIST” G1 is turned on.
POSSIBLE CAUSE: Inadequate amount of water.
SOLUTION: Please add water to the water tank.
POSSIBLE CAUSE: The power adapter is not connected to the device.
SOLUTION: Make sure the power adapter is connected to the product. To check whether the connection is successful, please remove the plug from this product and reconnect it
PROBLEM 2: No spray or abnormal spray
POSSIBLE CAUSE: Inadequate amount of water.
SOLUTION: Please add water to the water tank if there is not enough. If the water level inside the water tank is higher than the maximum water level mark, the mist will be sprayed irregularly, abnormally. Drain the water so that it is below the “MAX” level.
POSSIBLE CAUSE: The ultrasonic spray chip (K) is dirty.
SOLUTION: Please clean the water tank (E) and chip (K).
POSSIBLE CAUSE: Lower air inlet holes (H) are dusty.
SOLUTION: If the air inlet holes (H) are dusty, the volume of air drawn in will be reduced significantly and the air momentum will not be enough to spray the mist. Clean the air intake.
PROBLEM 3: Leakage
POSSIBLE CAUSE: Inner (C) and top cover (B) are not closed properly.
SOLUTION: Close both covers securely.
POSSIBLE CAUSE: Room temperature is too low or humidity is too high.
SOLUTION: If the temperature or humidity of the working environment is too low or too high, mist and water drops will accumulate on the surface of the device. Turn off the device.

CLEANING AND MAINTENANCE

Please clean the device according to the steps below every 3 days of use:

  1. When cleaning, disconnect the device from the mains.
  2. Open the top cover (B), pour out all the remaining water from the water tank by gently shaking the device.
  3. Dilute a little neutral kitchen detergent in warm water, then clean the device with a cloth.
  4. If you notice dirt on the inside of the air outlet (D), remove the top cover (B) and clean it.
  5. Please do not use medical diluent phenylethanol for maintenance, otherwise the device may be damaged.
  6. If it is not used for a long time, pour out the remaining water from the water tank (E), and store the device in a dry and cool place after cleaning.

Technical data:

24V 0.5A (12W)
Water tank volume: 100ml
Mist capacity: 20-30ml/hour
Ultrasonic frequency: 2.4MHz
Included: adapter

 To protect your environment: please separate carton boxes and plastic bags and dispose them in corresponding waste bins. Used appliance should be delivered to the dedicated collecting points due to hazarsous components, which may effect the environment. Do not dispose this appliance in the common waste bin.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

camry User Manuals

Related Manuals