50 717.1 Recessed Ceiling Luminaire for Indoor Use

Instructions for use

Application

Recessed ceiling luminaire · indoor luminaire with hand-blown opal glass, satin matt and aluminium alloy housing.
For installation into ceilings with a shallow depth in interior areas.

Product description

Recessed ceiling luminaire »ACCENTA« Die-cast aluminium housing Hand-blown opal glass, satin matt, with screw neck Ceiling trim ring made of metal, Colour white Recessed opening ø 68 mm Required installation depth 60 mm Fixing is achieved by using 2 adjustable wedge-shaped claws External LED power supply unit 220-240 V 0/50-60 Hz DC 176-280 V DALI controllable A basic isolation exists between power cable and control line Safety class II
– Safety mark
– Conformity mark
Weight: 0.38 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp

Module connected wattage 5.8 W
Luminaire connected wattage 7.7 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C

50 717.1 K27

Module designation LED-0922/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 920 lm
Luminaire luminous flux 632 lm
Luminaire luminous efficiency 82,1 lm / W

50 717.1 K3

Module designation LED-0922/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 940 lm
Luminaire luminous flux 650 lm
Luminaire luminous efficiency 84,4 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
The recessed opening will be covered by the frame of the luminaire.
Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.

Installation into false ceilings

A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch).
The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the panel must be no more than 20 mm.
The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires.
The connection of the control cables is achieved by means of the both leads marked with – DALI.
In case these leads are not used the luminaire will be operated at full light output.
Push external LED-power supply unit and luminaire housing into ceiling cut- out.
Luminaire housing and external LEDpower supply unit must not be installed in heat-insulating material.
Hand-tight screws of claw fasteners evenly.
Lead enclosed ceiling frame ring over the screw-neck of the glass and push it down the gasket.
Make sure that gasket is positioned correctly.
Insert glass with frame ring by turning it clockwise into luminaire housing.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA eplacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass with ceiling frame ring from luminaire housing by turning it counterclockwise.
Please follow the installation instructions for the LED module.
Check gasket.
Screw in glass with ceiling frame ring by turning it clockwise beyond the stop.
Defective glass must be replaced.
Spares

Spare glass 11 003 011 40R G
LED power supply unit DEV-0434/350
LED module 2700 K LED-0922/927
LED module 3000 K LED-0922/930
Trim ring 72 009 561 L
Gasket 83 001 412

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 50 717.1 Recessed Ceiling Luminaire for Indoor Use [pdf] Instruction Manual
50 717.1 Recessed Ceiling Luminaire for Indoor Use, 50 717.1, Recessed Ceiling Luminaire for Indoor Use, Recessed Ceiling Luminaire, Ceiling Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals