Application
- Recessed ceiling luminaire · indoor luminaire with symmetrical broad spread light distribution and a remote controllable power supply unit.
- For surface-mounted installation in indoor suspended ceilings of 5-30 mm thickness.
Product Description
- Recessed ceiling luminaire »STUDIO LINE« with a remote power supply unit
- Luminaire housing made of cast aluminum
- Ceiling trim ring finish, Colour velvet black inside hue matt copper
- Fixing is achieved by using 2 fastening springs
- Recessed opening ø 120 mm
- Required installation depth of 80 mm
- Light-diffusing disc
- External LED power supply unit: 220-240 V x 0/50-60 Hz
- DC 176-275 V
- DALI controllable
- Basic isolation exists between the power cable and the control line
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class: II
- CE: Conformity mark
- Weight: 0.45 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Specifications
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
- Module connected wattage: 10 W
- Luminaire connected wattage: 11.8 W
- Rated temperature: ta = 25 °C
- Ambient temperature: ta max = 45 °C
51 075.6 K3
- Module designation: LED-0859/930
- Colour temperature: 3000 K
- Colour rendering index: CRI > 90
- Module luminous flux: 1450 lm
- Luminaire luminous flux: 537 lm
- Luminaire luminous efficiency: 45,5 lm / W
preliminary data
Lighting technology
- Symmetrical wide beam light distribution Half beam angle 65°
Installation
- Luminaire housing and external LED power supply unit must not be covered by any heat insulating materials.
- LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
- Cover the recessed opening with the stop ring of the luminaire housing.
- The luminaire housing is then fixed in the recessed opening via two springs.
Installation in suspended ceilings
- A recessed opening of 120 mm with a minimum depth of 80 mm is required.
- The minimal thickness of the ceiling panel must be 5 mm and must not be greater than 30 mm.
- A ceiling panel with less than 5 mm thickness must be reinforced on the reverse.
- The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
- Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires.
- The connection of the control cables is achieved by means of the both leads marked with – DALI.
- In case these leads are not used the luminaire will be operated at full light output.
- Guide the LED power supply unit through the opening in the ceiling and position it on the suspended ceiling.
- Compress the fastening springs of the luminaire housing on both sides and slide the luminaire housing into the recessed opening.
- The fastening springs lock into place behind the ceiling panel.
Maintenance
Cleaning ·Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Close the luminaire.
Spares
- LED power supply unit: DEV-0385/350i
- LED module 3000 K: LED-0859/930
- Reflector: 71 003 294 L3