Product Information
This product is a luminaire with the following features:
- Die-cast aluminium housing
- Hand-blown opal glass, satin matt, with screw neck
- Fixing is achieved by using 2 adjustable wedge-shaped claws
- Contains light sources of energy efficiency class(es) D
Product Usage Instructions
Please follow these instructions for safe and proper usage of the product:
- Ensure that the installation and operation of this luminaire comply with national safety regulations.
- Installation and commissioning should only be carried out by a qualified electrician.
- Avoid improper use or installation to prevent damage. The manufacturer does not accept liability for such damage.
- If modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.
- For overvoltage protection, separate overvoltage protection components are recommended. Visit www.bega.com for more information.
- When installing the luminaire, avoid touching the light output opening of the LED directly.
- The electrical connection should be made in accordance with the protection class of the LED power supply. Use a distribution box and ensure correct wiring.
- Connect the power supply to the brown (L) and blue (N) wires.
DIMENSION
Instructions for use
Application
Recessed ceiling luminaire · indoor luminaire with hand-blown opal glass,
satin matt, and aluminium alloy housing. For installation into ceilings with a
shallow depth in interior areas.
Product Description
- Recessed ceiling luminaire »ACCENT«
- Die-cast aluminum housing
- Hand-blown opal glass,
- satin matt, with screw neck
- Ceiling trim ring is made of metal, Colour white
- Recessed opening ø 68 mm
- Required installation depth of 60 mm
- Fixing is achieved by using 2 adjustable
- wedge-shaped claws
- External LED power supply unit
- 220-240 V x 0/50-60 Hz
- Safety Class II 2
- r – Safety mark
- c – Conformity mark
- Weight: 0.39 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve additional protection
against e. g. transients, etc. we recommend separate overvoltage protection
components. You can find them on our website at
www.bega.com.
Lamp
- Module connected wattage 5.8 W
- Luminaire connected wattage 7.4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
- When installed in heat-insulating
- material ta max = 35 °C
- 50 716.1 K27
- Module designation LED-0922/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 890 lm
- Luminaire luminous flux 632 lm
- Luminaire luminous efficiency 85,4 lm / W
- 50 716.1 K3
- Module designation LED-0922/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 915 lm
- Luminaire luminous flux 650 lm
- Luminaire luminous efficiency 87,8 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. The recessed opening will be covered by the frame of the luminaire. Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.
Installation into false ceilings
- A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch).
- The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the panel must be no more than 20 mm.
- The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
- Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires.
- Push external LED-power supply unit and
- luminaire housing into ceiling cut-out.
- Hand-tight screws of claw fasteners evenly.
- Lead enclosed ceiling frame ring over the screw-neck of the glass and push it down the gasket.
- Make sure that gasket is positioned correctly.
- Insert glass with frame ring by turning it clockwise into luminaire housing.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect from main supply. Unscrew glass with
the ceiling frame ring from luminaire housing by turning it counterclockwise.
Please follow the installation instructions for the LED module. Check gasket.
Screw in glass with ceiling frame ring by turning it clockwise beyond the
stop. Defective glass must be replaced.
Spares
- Spare glass 11 003 011 40R G
- LED power supply unit DEV-0279/350
- LED module 2700 K LED-0922/927
- LED module 3000 K LED-0922/930
- Trim ring 72 009 561 L