BEGA 50494.5 Ceiling Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA-LOGO

BEGA 50494.5 Ceiling Luminaire

Product Information

The product is a luminaire that requires installation and operation in accordance with national safety regulations. It is recommended to have a qualified electrician carry out the installation and commissioning. The manufacturer will not be liable for any damage caused by improper use or installation. The luminaire is equipped with electronic components that are protected against overvoltage according to DIN EN 61547. Additional overvoltage protection components are recommended for enhanced protection. The product has a lamp module with a connected wattage of 25W and a luminaire- connected wattage of 27.8W. The rated temperature is 25°C and the ambient temperature should be between 45°C maximum and -25°C minimum. The luminaire has a module designation of LED-0785/830 with a color temperature of 3000K, a color rendering index (CRI) greater than 80, a module luminous flux of 4365lm, luminaire luminous flux of 3339lm, and luminaire luminous efficiency of 120.1lm/W.

Product Usage Instructions

  1. During installation or relamping, avoid touching the light output opening of the LED directly.
  2. Remove the mounting plate from the luminaire housing.
  3. Unplug the earth conductor connection (plug contact). If mounting onto a metallic, electroconductive surface, ensure that the mounting surface is connected conductively to the earth conductor of the luminaire.
  4. Mount the mounting plate so that the protective conductor screws are parallel to the surface to be illuminated. Pay attention to the required direction of light emission when arranging the mounting plate.
  5. Precisely position the luminaire housing in relation to the mounting plate, ensuring that the vertical bar inside the housing aligns with the mounting hole on the long bar of the mounting plate.
  6. To replace the LED module, note the designation of the module from the label in the luminaire.
  7. Disconnect the electrical installation and open the luminaire.
  8. Follow the installation instructions for the LED module and then close the luminaire.

Dimension

Instructions for use

Application

  • Ceiling luminaire downlight · Indoor luminaire with asymmetrical light distribution.

Product Description

  • Ceiling luminaire downlight »GENIUS«
  • Die-cast aluminum housing,
  • Color velvet black finish
  • Trim ring · Chrome finish
  • Matt safety glass
  • Optical silicone lens · BEGA Constant Optics®
  • Reflector surface made of pure aluminium 2 mounting holes ø 4.5mm
  • Distance apart 153mm
  • Connecting terminals 2.5@
  • Earth conductor connection
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 170-276 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Impact strength IK08
  • Protection against mechanical impacts < 5 joule
  • r – Safety mark
  • c – Conformity mark
  • Weight: 2.2 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 25 W
  • Luminaire connected wattage 27.8 W
  • Rated temperature ta= 25 °C
  • Ambient temperature ta max= 45 °C

50 494.5K3

  • Module designation LED-0785/830
  • Color temperature 3000 K
  • Color rendering index CRI > 80
  • Module luminous flux 4365 lm
  • Luminaire luminous flux 3 339 lm
  • Luminaire luminous efficiency 120,1 lm/W

Lighting technology

  • Half beam angle 65/68°

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Remove mounting plate from the luminaire housing.
  • Unplug the earth conductor connection (plug contact).

Please note:

  • If the luminaire is to be mounted onto a metallic, electroconductive surface, it is mandatory to make sure that the mounting surface is connected conductive to the earth conductor of the luminaire!

IMPORTANT:

  • The mounting plate must be mounted so that the protective conductor screws of the mounting plate are parallel with the surface to be illuminated.
  • Pay attention to the required direction of the light emission when arranging the mounting plate.
  • If the light is to be emitted from the luminaire in the opposite direction, the mounting plate must be rotated by 180°.
  • Lead the power connecting cable through the mounting plate.
  • Ensure correct directionality towards the area to be illuminated.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Establish the earth conductor connection on the earthing screw (1) of the mounting plate.
  • Establish the earth conductor connection to the luminaire housing (plug contact).
  • Push silicone hoses over connecting wires and make the electrical connection at the terminal marked (L) and (N).
  • The two connecting terminals marked DA, DA are provided for digital control purposes.
  • If these terminals are not assigned, the luminaire will work with full light output.

IMPORTANT:

  • To ensure secure connection, the luminaire housing must be positioned precisely in relation to the mounting plate.
  • Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate.
  • Press the luminaire housing firmly against the mounting plate and turn it clockwise as far as it will go.
  • The exact alignment is achieved by turning back the luminaire by max. 30°.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the electrical installation.
  • Open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0391/500
  • LED module 3000 K LED-0785/830
  • Glass/Trim ring 75 002 941
  • Reflector 76 001 638M
  • BEGA Gantenbrink-Leuchten KG
  • Postfach 3160
  • 58689 Menden
  • info@bega.com
  • www.bega.com

Documents / Resources

| BEGA 50494.5 Ceiling Luminaire [pdf] Instruction Manual
50494.5 Ceiling Luminaire, 50494.5, Ceiling Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>