Product Information
-
Product Name: Recessed Luminaire
-
Model Number: 50 695.2
-
Product Description: Recessed luminaire without power supply unit. Luminaire housing made of cast aluminum. Installation housing is made of glass-fiber reinforced polyamide with 2 fastening springs. Reflector made of pure anodized aluminum.
Optical silicone lens. Ceiling trim ring finish, Stainless steel. -
Required Installation Depth: 125 mm
-
Weight: 2.4 kg
-
Energy Efficiency Class: E
-
Lamp Module Connected Wattage: 17.2 W
-
Luminaire Connected Wattage: 19.8 W
-
Color Temperature : 3000 K
-
Colour Rendering Index (CRI): >90
-
Module Luminous Flux: 2655 lm
-
L uminaire Luminous Flux : 1724 lm
-
Luminaire Luminous Efficiency : 87.1 lm / W
Product Usage Instructions
- The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning.
- Ensure that the luminaire housing is not installed in heat-insulating material.
- A separate power supply unit is required to operate the luminaire.
- Refer to the operating instructions of the LED power supply units for proper usage.
- Avoid touching the light output opening of the LED directly during installation or relamping.
For more information and overvoltage protection components, visit the BEGA website.
Dimension
Instructions for use
Application
- Recessed ceiling downlight · Interior luminaire with symmetrical narrow beam light distribution for connection to an external LED power supply unit.
- For surface-mounted installation in indoor suspended ceilings of 8-25mm thickness.
Product Description
- Recessed luminaire without power supply unit
- Luminaire housing made of cast aluminum
- Installation housing is made of glass-fibre reinforced polyamide with 2 fastening springs
- Reflector made of pure anodized aluminum
- Optical silicone lens
- Ceiling trim ring finish, Stainless steel
- Partially matt crystal glass
- Recessed opening ø 188mm
- Required installation depth 125mm 1 connecting cable with strain relief and plug connector system for BEGA power supply unit, on/off or DALI
- Safety Class III 3
- c – Conformity mark
- Weight: 2.4 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 17.2 W
- Luminaire connected wattage 19.8 W
- Rated temperature ta =25 °C
- Ambient temperature ta max =40 °C
50 695.2K3
- Module designation LED- 0785/930
- Color temperature 3000 K
- Color rendering index CRI > 90
- Module luminous flux 2655 lm
- Luminaire luminous flux 1724 lm
- L uminaire luminous efficiency 87,1 lm/W
Lighting technology
- Half beam angle 50°
Installation
- Luminaire housing must not be installed in heat-insulating material.
- A separate power supply unit is required to operate the luminaire.
- For connection to external LED-power supply unit – accessory 13 144 or 13 170 – the luminaire is equipped with a 2-pin connector.
- Note operating instructions of the LED-power supply units.
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- The recessed opening is covered by the frame of the luminaire housing.
- Fixing of the installation housing in the recessed opening is achieved by using two adjustable springs.
Installation into inserted ceilings:
- A recessed opening of 188 mm is necessary to accept the installation housing. Recessed depth min. 125 mm.
- The lateral distance between recessed luminaire and other building parts must be at least 50 mm.
- Compress the fastening springs of the installation housing against their spring pressure on both sides towards the housing and slide the installation housing into the recessed opening.
- The fastening springs catch the ceiling panel from the back side. Minimum thickness of the ceiling panel is 8 mm. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the ceiling panel must be no more than 25 mm.
- Push the enclosed threaded rods through the two inside openings of the installation housing and guide the clamping angle of the threaded rods downwards onto the suspended ceiling. Clip the threaded rods into their guide grooves and screw them in by hand as far as possible.
- Fix in end position with screwdriver (TX 10).
- This clamp fixing prevents the installation housing from turning and dropping.
- Connect to the LED power supply unit.
- Route the LED power supply unit through the installation housing and place it in the suspended ceiling.
- Connect the 2-pin plug connector between luminaire and external LED power supply unit.
- Press together the two internal fixing sliders inside the luminaire housing.
- Push the luminaire housing to the end of the installation housing and then release the fixing sliders.
- This mechanism ensures that the luminaire housing sits securely inside the installation housing.
- Installation housing and external LED power supply unit must not be installed in heat-insulating material.
- Please use the protective gloves provided for the installation to prevent fingerprints on the reflector.
- Place the reflector with silicone lens onto the glass. Twist the glass with the attached reflector to the right to fix the assembly inside the luminaire housing.
Cleaning · Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Close the luminaire.
Accessories
- Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.
- 13 144 Power supply unit on/off
- 13 170 Power supply unit DALI
- The power supply units are only suitable for the operation of one LED luminaire
- For the accessories, separate instructions for use can be provided upon request.
Spares
- LED module 3000 K LED-0785/930
- Reflector 75 002 753
- Spare glass 75 002 914
- BEGA Gantenbrink-Leuchten KG
- Postfach 3160
- 58689 Menden
- info@bega.com
- www.bega.com
Documents / Resources
| BEGA
50695.2 Recessed Ceiling
Luminaire
[pdf] Instruction Manual
50695.2 Recessed Ceiling Luminaire, 50695.2, Recessed Ceiling Luminaire,
Ceiling Luminaire, Luminaire
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>