BEGA 50 262 Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
Technical amendments reserved
Wall luminaire for indoor use
50 262
50 262 Wall Luminaire
Instructions for use
Application
Free-radiating wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks.
Product description
Metal housing, finish colour white Hand-blown opal glass, satin matt 2
elongated fixing holes
Width 4.5 mm · 185 mm spacing 1 cable entry for through-wiring for mains cable
Connecting terminals 2.5°
Earth conductor connection
LED-Module for mains voltage
220-230 V 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
– Safety mark
– Conformity mark
Weight: 0.95 kg
This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Luminaire connected wattage | 10 W |
---|---|
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 35 °C |
50 262 K3
Module designation | LED-0607/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | Ra > 90 |
Module luminous flux | 940 lm |
Luminaire luminous flux | 750 lm |
Luminaire luminous efficiency | 75 lm / W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Establish earth conductor connection and make the electrical connection to the
terminals.
Advice:
Expansion of glass and metal is different.
Glass must be allowed to expand.
Place glass into the luminaire base and fix set screws handtight.
After tightening the set screws loosen them for half a turn to allow the glass
to move.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by a
qualified electrician or a comparably qualified person using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass | 11 003 223 .0R G |
---|---|
LED module 3000 K | LED-0607/930 |
Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>