The Kompakttiefstrahler Compact downlight Spot compact is a compact downlight with symmetrical narrow beam light distribution. It is made of aluminium alloy, aluminium, and stainless steel. The luminaire has a safety glass with optical structure and a reflector surface made of pure aluminium. It has a width of 6.5 mm and a distance of 150 x 110 mm. The LED power supply unit operates at 220-240 V x 0/50-60 Hz DC 176-280 V. The luminaire has a protection class IP 65, making it dust-tight and protected against water jets. It also has an impact strength of IK09.
The product contains light sources of energy efficiency classes E.

Product Usage Instructions

  1. The installation and operation of this luminaire should be carried out by a qualified electrician in accordance with national safety regulations.
  2. The manufacturer does not accept liability for damage caused by improper use or installation. Any modifications made to the luminaire should be done by a responsible person who will be considered the manufacturer.
  3. The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. For additional protection against transients, etc., separate overvoltage protection components are recommended. These can be found on the manufacturer’s website at www.bega.com.
  4. The luminaire has a rated temperature and can be used within the specified ambient temperature range.

DIMENSION

BEGA-24066-Compact-Downlight-fig-2

Application

Compact downlight with symmetrical narrow beam light distribution.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass with optical structure
  • Reflector surface made of pure aluminium BEGA Vortex Optics®
  • Mounting plate with 4 elongated holes,  width 6.5 mm, distance 150 x 110 mm Connection box with 2 cable entries for through-wiring of the mains supply cable ø 5-13 mm, max. 5×2,5@
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-280 V
  • During DC operation the LED power is reduced to 15 %
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • p Ballproof according to DIN VDE 0710 part 13
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK09
  • Protection against mechanical
  • impacts < 10 joule
  • r – Safety mark
  • c  – Conformity mark
  • Weight: 5.3 kg
  • This product contains light sources of energy efficiency classes E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to
  • the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against
  • e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

PRODUCT SPECIFICATION

  • Lamp
    • Module connected wattage 62.2 W
    • Luminaire   connected wattage 69 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 40 °C
  • 24 066 K3
    • Module designation LED-1002/830
    • Colour temperature 3000 K
    • Colour rendering index CRI > 80
    • Module luminous flux 10760 lm
    • Luminaire luminous flux 5554 lm
    • Luminaire luminous efficiency 80,5 lm / W
  • 24 066 K4
    • Module designation LED-1002/840
    • Colour temperature 4000 K
    • Colour rendering index CRI > 80
    • Module luminous flux 10910 lm
    • Luminaire luminous flux 5626 lm
    • Luminaire luminous efficiency 81,5 lm / W

Lighting technology

Symmetrical narrow beam light distribution Half beam angle 20°

Installation

  • Loosen the grub screw (wrench size 3 mm) at the side and remove the mounting plate from the luminaire housing.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.

BEGA-24066-Compact-Downlight-fig-3

  • Hook the end of the steel wire from the luminaire housing into the recess on the mounting plate.
  • To secure the steel wire, screw the hexagon socket screw (Pos. A) into the hole (Pos. B).

BEGA-24066-Compact-Downlight-fig-4

  • Undo the hexagon socket screws and open the connection box.
  • Run the luminaire power supply cable through the PG 9 cable gland and the power connecting cable through the M20 cable gland and into the connection box. For through-wiring, the factory-fitted dummy plugs must be removed.
  • Tighten the cable glands securely.
  • Make the earth conductor connection and the electrical connection (see illustration). Observe the correct configuration of the connecting cable. Connect the live conductor to the brown wire (L), the neutral conductor to the blue wire (N) and the earth conductor to the green-yellow wire marked (PE).
  • The control cables are connected using the two wires marked DALI.
  • If these wires are not assigned, the luminaire will work with full light output.
  • Make sure the gasket is properly located. Close the junction box and slide under the retaining bracket on the mounting plate.
  • Hook the connection cable into the retainer (see illustration).

BEGA-24066-Compact-Downlight-fig-5

  • Insert the luminaire housing into the mounting plate and push it into the four guides as far as it will go.
  • As you do so, make sure that all four retention bolts of the luminaire housing are firmly seated in the guides of the mounting plate and that it is no longer possible to remove the luminaire. Screw in the grub screw on the side up to the stop in order to lock the luminaire in place. You must not feel any resistance when you do this. If you do, check that the luminaire housing is correctly seated in the mounting plate.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Trim frame graphite with glass 25 000 019
  • Trim frame white with glass 25 000 020
  • LED power supply unit DEV -0300/1800
  • LED module 3000 K LED-1002/830
  • LED module 4000 K LED-1002/840
  • Reflector 76 001 868 B1
  • Gasket connection box 83 001 873
  • Gasket housing 83 001 905
  • Gasket Luminaire base 83 001 944