BEGA 33523 LED Ceiling and Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 33523 LED Ceiling and Wall Luminaire
Product Information
The Decken- und Wandleuchte is a ceiling and wall luminaire that is designed for various lighting tasks. It has a high protection class and is made of an aluminium alloy and crystal glass.
The luminaire is available in two models:
- Model 33 523 K3:
- Module designation: LED-0381/930
- Colour temperature: 3000 K
- Colour rendering index (CRI): > 90
- Module luminous flux: 1755 lm
- Luminaire luminous flux: 1057 lm
- Luminaire luminous efficiency: 90.3 lm/W
- Model 33 523 K4:
- Module designation: LED-0381/940
- Colour temperature: 4000 K
- Colour rendering index (CRI): > 90
- Module luminous flux: 1860 lm
- Luminaire luminous flux: 1120 lm
- Luminaire luminous efficiency: 95.7 lm/W
Instructions for use
Application
Ceiling and wall luminaire with high protection class for a variety of
lighting tasks. A luminaire made of aluminium alloy and crystal glass.
Lamp
- Module connected wattage
- Luminaire connected wattage
- Rated temperature
- Ambient temperature
33 523 K3
- Module designation
- Colour temperature
- Colour rendering index
- Module luminous flux
- Luminaire luminous flux
- Luminaire luminous efficiency
33 523 K4
- Module designation
- Colour temperature
- Colour rendering index
- Module luminous flux
- Luminaire luminous flux
- Luminaire luminous efficiency
Product Usage Instructions
-
Safety
Before installing and operating the luminaire, ensure that you comply with national safety regulations. The installation and commissioning should only be carried out by a qualified electrician. The manufacturer is not liable for any damage caused by improper use or installation. If you make modifications to the luminaire, you will be considered the manufacturer.
-
Overvoltage Protection
The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection against transients and other events, it is recommended to use separate overvoltage protection components. You can find these components on the manufacturer’s website at www.bega.com.
-
Installation
When installing the luminaire, make sure to only operate it with the complete protective cover. Undo the locking screw and turn the cover ring as far as it will go. Remove the cover ring and glass from the luminaire base. During installation or relamping, avoid touching the light output opening of the LED directly, as they are high-quality electronic components.
-
Spares
If you require spare parts, the following are available:
- Spare glass: 11 002 865
- LED power supply unit: 11 DEV-0340/350
- LED module 3000 K: LED-0381/930
- LED module 4000 K: LED-0381/940
- Gasket: 83 001 382
Product Description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Crystal glass with white matt finish
- Silicone gasket
- 2 mounting holes ø 4.5 mm
- Distance apart 200 mm
- Two cable entries for through-wiring power connecting cable up to 10.5 mm in diameter, max. 5 x 1.5 qmm.
- Connection terminal 2.5@
- Earth conductor connection
- 2-pole connecting terminal for digital control
- BEGA Ultimate Driver®
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-264 V
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK07
- Protection against mechanical impacts < 2 joule
- – Safety mark
- – Conformity mark
- Weight: 2.6 kg
- This product contains light sources of energy efficiency classes C, D
Installation
The luminaire must only be operated with the complete protective cover. Undo locking screw and turn cover ring as far as it will go. Remove cover ring and glass from the luminaire base. LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Disassemble LED module. Loosen LED connection (plug connection). Lead the mains supply cable through the cable entry into the luminaire back housing. Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Be sure to use the gasket rings supplied. Make the earth conductor connection and the electrical connection. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. Push LED plug into the coupler as fa as it will go. Make sure that gasket is positioned correctly. Assemble LED module. Tighten the screws evenly. Please observe that the LED board is not damaged mechanically. Place cover ring with glass onto the luminaire base and turn it clockwise as far as it will go. Tighten locking screw.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Inspect and,
if necessary, replace the luminaire gaskets. Defective glass must be replaced.
Close the luminaire.
Spares
- Spare glass: 11 002 865 11
- LED power supply unit: DEV-0340/350
- LED module 3000 K: LED-0381/930
- LED module 4000 K: LED-0381/940
- Gasket: 83 001 382
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References