Product Information

  • The product is a luminaire made of aluminum alloy with a matt safety glass and a reflector made of pure anodized aluminum.
  • It comes with a mounting plate for bolting onto a foundation or connecting housing, which is made of stainless steel.
  • The luminaire has a LED power supply unit that operates at 220-240 V and 50-60 Hz, with a DC output voltage range of 176-264 V. It is DALI controllable and supports DT8, RGBWAF, and xy control protocols.
  • The luminaire has a basic isolation between the power cable and control line.
  • It has a protection class of IP 67, making it dust-tight and resistant to temporary immersion.
  • The luminaire also has an impact strength of IK07, providing protection against mechanical damage.

Product Usage Instructions

  1. Safety: The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning. The manufacturer will not be liable for any damage caused by improper use or installation. If any modifications are made to the luminaire, the person responsible for those modifications will be considered the manufacturer.

  2. Overvoltage Protection: The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients and other risks, it is recommended to use separate overvoltage protection components. You can find these components on the manufacturer’s website at www.bega.com.

  3. Electrical Connections: Connect the luminaire to a power source with a voltage range of 220-240 V and a frequency of 50-60 Hz. Ensure that the DC output voltage from the power supply unit is within the range of 176-264 V. Use appropriate cables and
    connectors for the electrical connections.

  4. Mounting: Use the provided mounting plate to securely attach the luminaire onto a foundation or connecting housing. Ensure that the mounting plate is properly aligned and tightened to prevent any movement or instability.

  5. Thermal Regulation: The luminaire has a temporary thermal regulation feature to protect temperature-sensitive components without switching off the luminaire. This ensures optimal performance and longevity of the product.

  6. Maintenance: Regularly clean the luminaire to remove any dust or dirt that may accumulate on the surface. Use a soft cloth or non-abrasive cleaning agent to avoid damaging the finish. Inspect the luminaire
    for any signs of damage or wear and replace any faulty components as necessary.

  7. Compliance: Ensure that the usage of the luminaire complies with all applicable regulations and standards in your area, including electrical safety and environmental requirements. For more detailed information and specific usage instructions, please refer to the complete user manual available on the manufacturer’s website at www.bega.com.

Surface-mounted luminaire RGBW

BEGA-84-874-Surface-Mounted-Luminaire-RGBW-01

Instructions for use

Application

  • Surface-mounted luminaire · Wall washer The design of this in-ground floodlight makes it possible to fully illuminate a vertical surface, e.g. a façade, from the ground to the lower edge of the roof. The lower limit of the light distribution is a straight line, without the usual “light cone”.
  • The luminaire can be controlled by DALI color light control (DT 8, RGBWAF, xy).
  • We recommend the use of BEGA DALI system components.
  • For the various requirements at the installation site, we offer a connection housing as a accessory.
  • The luminaires can thus be installed on unpaved surfaces.

Lamp

  • Module connected wattage: 23.2 W
  • Luminaire connected wattage: 26.6 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 40 °C
  • Module designation: LED-0903/RGBW
  • Color temperature of the white: LED 4000 K
  • Luminaire luminous: flux 1909 lm
  • Luminaire luminous efficiency: 71,8 lm / W

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Product description

  • Luminaire made of aluminum alloy, aluminum and stainless steel
  • BEGA Tricoat® coating technology Matt safety glass
  • Reflector made of pure anodized aluminum
  • Luminaire with mounting plate for bolting onto a foundation or onto a connecting housing
  • Mounting plate made of stainless steel
  • Steel grade number 1.4301
  • 4 elongated fixing holes
  • Width 9 mm · 170 x 170 mm spacing
  • 3 elongated fixing holes
  • Width 9 mm · pitch circle ø 132 mm
  • 1,8 m water-resistant connecting cable
  • 07RN8-F 5 G 1@ with implemented water
  • stopper and 1.2 m PVC cable conduit
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI controllable (DT8, RGBWAF, xy)
  • A basic isolation exists between power cable and control line BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 67
  • Dust-tight and protection against temporary immersion
  • Impact strength IK07
  • Protection against mechanical impacts < 2 joule
  • Maximum surface temperature 35 °C (measured according to EN 60598 of ta 15 °C)
  • – Conformity mark
  •  – Safety mark
  • Weight: 5.6 kg
  • This product contains light sources of energy efficiency classes F

Installation

  • The base of the luminaire must not be below the upper edge of the floor covering.

  • Disassemble mounting plate.

  • Undo hexagon socket head screws (wrench size 4) through the opening in the floodlight housing up to the stop and lift floodlight housing.
    BEGA-84-874-Surface-Mounted-Luminaire-RGBW-04

  • Installation on foundations provided by the customer or on other paved surfaces (ill. A):

    • For the electrical connection and for accepting the connecting cable with water stopper a cavity of ø 50 mm is required under the luminaire at site.
    • Sufficient drainage must be provided.
    • If the luminaire connecting cable is laid in the soil the enclosed protective conduit must be used.
  • Fix mounting plate with enclosed or any other suitable fixing material onto the foundation. Installation onto a connection housing (ill. B):

    • Fix mounting plate onto the connection housing (BEGA accessory 71 246).
  • The electrical connection must be carried out with matching protection class and safety class with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.

  • We recommend the use of distribution box 70 730 for this purpose.

  • Make the earth conductor connection and the electrical connection.

  • Note correct configuration of the mains supply cable. Make mains supply connection at the brown (L), blue (N) and green-yellow lead ( ).

  • The connection of the control cables is achieved by means of the both leads marked with DALI.

  • In case these leads are not used the luminaire will be operated at full light output.

  • Place floodlight housing onto luminaire base and fix with screws.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.
  • Corrosive chemicals must not come in contact with the luminaire.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the electrical installation.
  • To open the luminaire hexagon socket head screws (wrench size 4 mm) through the opening in the floodlight housing up to the stop and lift floodlight housing.
  • Undo the hexagon socket head screw (wrench size 5 mm) in the luminaire base and remove covering cap.
  • Replace LED module.
  • Note installation instructions of the LED module.
  • Check the gasket and replace, if necessary.
  • Tighten the screw cable gland.
  • Check all screws and threads thoroughly and grease them.
  • Assembly to be carried out in reverse sequence.

Accessories

  • 71 246 Connection housing made of galvanized steel Total length 225 mm
  • 70 730 Distribution box
    • The distribution box is meant for installation in the soil and allows a junction from the supply cable to the luminaire and through-wiring to the next luminaire.
    • After the electrical connection the distribution box is filled up with gel and closed.
    • For the accessories a separate instructions for use can be provided upon request.

Spares

  • LED power supply unit DEV-0418/150i
  • LED module LED-0903/RGBW
  • Reflector 76 001 813
  • Gasket 83 001 801