BEGA 50807.5 Wall Luminaire Instruction Manual

June 12, 2024
BEGA

50 807.5 ****

Wall luminaire for indoor useBEGA 508075 Wall
Luminaire

Instructions for use

Application

Wall luminaire · indoor luminaire for the glare free illumination of wall surfaces with the mounting surface being the reflection surface. The light emits upwards and downwards.

Product description

Luminaire housing made of aluminium, finish Colour velvet black
Synthetic cover with light diffusing structure Reflector made of pure anodised aluminium 2 elongated fixing holes
Width 5.5 mm · 1450 mm spacing 1 cable entry for through-wiring for mains cable
Connection terminal 2.5@
Earth conductor connection
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-280 V
During DC operation the LED power is reduced to 15 %
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Impact strength IK04
Protection against mechanical impacts < 0.5 joule
– Safety mark
****– Conformity mark
Weight: 9.3 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Komponenten sind nach DIN EN 61547 gegen
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Lamp

Module connected wattage 122 W
Luminaire connected wattage 130 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C

50 807.5 K3

Module designation 10x LED-1049/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 18300 lm
Luminaire luminous flux 15595 lm
Luminaire luminous efficiency 120 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Undo the hexagon socket head screws (wrench size 3 mm) and lift luminaire top. Loosen earth connection (plug connection) and LED-connection between luminaire top and luminaire base. Lead the mains supply cable through the cable entry of the luminaire base. Note position of application “arrow down”. Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface. Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection. For digital control please use the connecting terminal DA, DA. In case this terminal is not used the luminaire will be operated at full light output. Make earth connection (plug connection) and LED-connection between luminaire top and luminaire base again.
Note position of application of the luminaire “arrow down”. Install luminaire top part, adjust it and tighten screws evenly.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Undo one of the two external locking screws (Torx) in the luminaire housing and remove the lateral housing cover. Remove the synthetic cover from the profile of the luminaire housing. Remove the LED module. Install the replacement LED module. Please follow the installation instructions for the LED module. A defective synthetic cover must be replaced. Close up the luminaire again in reverse order.
Spares

Synthetic cover 15 000 631
LED power supply unit DEV-0390/700i
LED module 3000 K LED-1049/930
Reflector short 76 001 896 B1
Reflector long 76 001 896 B2

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com